Fault

Cause

Measure

Product does not
start up:

No hot water

Heating re-
mains cold

The system pressure is insufficient.
Low water pressure in the heating in-
stallation (fault message:

F.22

).

Fill the heating installation (

"Filling the heating installation"
section).

There is air in the heating installation.

Have your competent person
purge the heating installation.

After three unsuccessful attempts to
ignite the flame, the product switches to
fault mode (fault message:

F.28

).

Press the fault clearance key for
one second. The product makes
another attempt to ignite the
flame.
If you have been unable to elim-
inate the ignition fault after three
fault clearance attempts, consult a
competent person.

Hot water gener-
ation functioning
correctly; heating
does not start up.

The external controller is not set cor-
rectly.

Set the external controller cor-
rectly (

Controller operating in-

structions).

Содержание ecoFIT pure

Страница 1: ...Operating instructions ecoFIT pure 825 835 GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de...

Страница 2: ...4 8 Setting the heating flow temperature 11 4 9 Setting the hot water temperature 11 4 10 Switching Comfort mode on and off 12 4 11 Switching off the product s functions 12 4 12 Guaranteeing the corr...

Страница 3: ...t ing installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with...

Страница 4: ...Avoid rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mai...

Страница 5: ...the expansion relief valve to the drain pipework to constructional condi tions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion a...

Страница 6: ...ial damage due to maintenance and repairs carried out incorrectly or not carried out at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be...

Страница 7: ...umber Article number Gas Coun cil Number VUW 256 6 3 H GB 0010020389 47 044 68 VUW 306 6 3 H GB 0010020390 47 044 74 VUW 356 6 3 H GB 0010020391 47 044 70 3 Product description 3 1 Front view 1 2 1 Co...

Страница 8: ...ired Information on the maintenance message in the Live Monitor Sym bol Meaning Explanation Summer mode active Heating mode is switched off Burner anti cyc ling time is active To avoid the need for fr...

Страница 9: ...that the products comply with the basic requirements of the applicable directives as stated on the iden tification plate The declaration of conformity can be viewed at the manufacturer s site 3 7 Benc...

Страница 10: ...e Scrolling through menu entries The current function of the and but tons is shown in the display Adjustable values are always displayed as flashing You must always confirm a change to a value Only th...

Страница 11: ...ating flow temperature appears on the display Note The competent person may have adjusted the maximum possible temperature Conditions No controller connected Use or to set the required heating flow te...

Страница 12: ...e display 4 12 Guaranteeing the correct filling pressure of the heating system 4 12 1 Checking the filling pressure of the heating installation Note To ensure that the heating installa tion operates s...

Страница 13: ...water supply 7 Purge all radiators 8 Check the filling pressure in the display 9 Top up with more water if necessary 10 Close the filling cock 11 Return to the basic display Page 10 4 13 Protecting th...

Страница 14: ...arried out by a competent person is a prerequis ite for ensuring that the product is perman ently ready and safe for operation reliable and has a long working life 6 2 Caring for the product Caution R...

Страница 15: ...rson permanently decommission the product 8 Recycling and disposal The competent person who installed your product is responsible for the dis posal of the packaging If the product is identified with t...

Страница 16: ...and Hot water requirement S 22 DHW mode Pump pre run DHW mode Pump pre run S 24 DHW mode Burner on DHW mode Burner on Others S 31 No heat demand Summer mode Summer mode active S 34 Heating mode Frost...

Страница 17: ...competent person purge the heating installation After three unsuccessful attempts to ignite the flame the product switches to fault mode fault message F 28 Press the fault clearance key for one secon...

Страница 18: ......

Страница 19: ......

Страница 20: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Отзывы: