background image

3

Split Type User Manual

EN

Your Safety

1 .1 

Symbols used

 Danger!

Direct danger for life and health .

 Danger!

Danger of electric shock .

 Warning!

Potentially dangerous situation for the product 
and the environment

 

Note!
Useful information and indications.

1 .2 

Proper Use of the Unit

This unit has been designed and manufactured for 
acclimatisation purposes by means of air conditioning. 
The use thereof for other domestic or industrial 
purposes shall be the exclusive responsibility of the 
persons specifying, installing or using them in that way.

Prior to handling, installing, starting up, using or 
performing maintenance on the unit, the persons 
assigned to perform these tasks should be familiar with 
all the instructions and recommendations set forth in 
the unit's installation manual and in this user manual. 

Vaillant does not accept any responsability for damages 
that may arise from non-observation of the following 
instructions.

 

Note!
The Installation of the unit has to be done by 
qualified people. Do not install it yourself. All 
electrical repairs should be also carried out by 
qualified electricians

 

Note!
Please read this User Manual carefully before 
using the air conditioning.

 

Note!
Keep the manuals throughout the service life of 
the unit.

 

Note!
The information relating to this unit is divided 
between two manuals: installation manual and 
user manual.

 Note!

This equipment contains R-410A refrigerant. Do 
not vent R-410A into atmosphere: R-410A, is a 
fluorinated greenhouse gas, covered by Kyoto 
Protocol, with a Global Warming Potential (GWP) 
= 1975.

 Note!

The refrigerant fluid contained in this 
equipment must be properly recovered for 
recycling, reclamation or destruction before 
the final disposal of the equipment.

 Note!

The relevant personnel performing the 
maintenance operations related with the 
handling of the refrigerant fluid must have the 
necessary certification issued by local 
authorities.

Extreme Operating Conditions

This unit has been designed to operate within the range 
of temperatures indicated on Figure 2.1. Ensure that 
these ranges are not exceeded.

R

EFRIGERACIÓN

C

ALEFACCIÓN

Interior

Exterior

43ºC D.B.

18ºC D.B.

24ºC D.B.

-7ºC D.B.

32ºC D.B.

18ºC D.B.

30ºC D.B.

15ºC D.B.

Fig . 2 .1   Operating ranges of the unit .

Legend

D.B.  Temperature measured by dry bulb

Your Safety 1

Extreme Operating Conditions 2

Indoor

Outdoor

INVERTER: 45ºC D.B.

17ºC D.B.

17ºC D.B.

30ºC D.B.

24ºC D.B.

INVERTER: -15ºC D.B.

C

OOLING

H

EATING

30ºC D.B.

ON-OFF: 5ºC D.B.

ON-OFF: 43ºC D.B.

ON-OFF: -7ºC D.B.

INVERTER MONOS: -15ºC D.B.
INVERTER MULTIS: 0ºC D.B.

Содержание climaVAIR VAM 2-060 W2

Страница 1: ...VAI 2 025 WN VAI 2 035 WN VAI 2 050 WN VAI 2 065 WN VAM 2 050 W2N VAM 2 060 W2N VAM 2 085 W3N VAM 2 085 W4N VAI 2 025 W VAI 2 035 W VAI 2 050 W VAM 2 060 W2 climaVAIR DE EN HR IT TR...

Страница 2: ......

Страница 3: ...For the user User Manual Air Conditioner climaVAIR Split Type EN VAI2 VAM2...

Страница 4: ...ating Mode HEAT 13 7 6 Setting the Airflow Direction 14 7 6 1 Vertical Airflow 14 7 7 Special Function Selection 14 7 7 1 Health Anion Operation ION 14 7 7 2 SLEEP Function 15 7 7 3 TIMER ON OFF Funct...

Страница 5: ...g the air conditioning Note Keep the manuals throughout the service life of the unit Note The information relating to this unit is divided between two manuals installation manual and user manual Note...

Страница 6: ...ised of the following elements Outdoor unit Indoor unit Remote controller Interconnecting services Supplied accessories Figure 5 1 shows the unit components Fig 5 1 Unit components Legend 1 Indoor Uni...

Страница 7: ...city Anti bacterial filter Filter with an anti allergenic and anti bacterial effect which keeps the atmosphere clean and healthy Anti dust filter General filter which eliminates much of the dirt and d...

Страница 8: ...osition a few minutes later Remove the batteries in case the air conditioning is out of use for a long period If there is anything still showing on display just press the reset button Warning Danger o...

Страница 9: ...the air conditioning unit by pulling the cord Danger of injury and physical damage Danger of fire and explosion Damaged air conditioners should not be put into operation In case of doubt consult your...

Страница 10: ...on 7 CLOCK button 8 TIMER button 9 ION button 10 DEL button 11 FAN button 12 TURBO FP button 13 LIGHT LOCK button 14 FOLLOW ME button 7 2 2 Display Indicators Fig 7 2 Overview of the indicators Legend...

Страница 11: ...button for less than 2 seconds to light the display of the Indoor Unit To switch the display back off press the LIGHT LOCK button for less than 2 seconds once again 7 4 Turning the unit on and off In...

Страница 12: ...activate With the unit connected see section 7 4 Press the MODE button The different operation modes are displayed Fig 7 6 Operation modes Select the cooling operation mode COOL Press the TEMP TIME b...

Страница 13: ...n modes are displayed Fig 7 9 Operation modes Select the dehumidifying mode DRY Press the TEMP TIME buttons to select the temperature setting When pressing the TEMP TIME buttons the temperature config...

Страница 14: ...Fan selection mode Legend 1 MODE button 2 FAN mode indicator 3 FAN button In order to activate the fan mode FAN With the unit connected see section 7 4 Press the MODE button The different operation mo...

Страница 15: ...ig 7 16 Operation modes Select the heating operation mode HEAT Press the TEMP TIME buttons to select the temperature setting When pressing the TEMP TIME buttons the temperature configuration will incr...

Страница 16: ...button to direct the airflow upwards or downwards Once pressing air deflector will turn 6 degrees When pressing for over 3 seconds the vertical airflow enters AUTO mode 7 7 Special Function Selection...

Страница 17: ...ve the configured temperature Once an hour has elapsed the temperature will rise 1 C more The unit is operational for 7 hours before stopping In HEAT mode The ambient temperature decreases 2 C in rela...

Страница 18: ...previous steps successively When pressing the TEMP TIME buttons the time configuration will increase or decrease by 10 minutes If the TEMP TIME buttons are kept pressed the time will increase or decr...

Страница 19: ...en activated the remote control display shows the actual temperature at its location The remote control will send this infor mation to the indoor unit every 3 minutes so the tem perature at the locati...

Страница 20: ...ncy Operation Only use this function when the remote controller is broken or has been mislaid In order to activate Press the emergency operation switch A beeping noise is heard which indicates that th...

Страница 21: ...s windows ceiling and floor the adjacent rooms are cooler than the room temperature therefore thermal energy is unintentionally lost It is therefore difficult to adequately heat the room and an unplea...

Страница 22: ...ing mode or excessively low temperature in heating mode Set the temperature properly Obstacle in front of the air inlet or outlet Remove the obstacle to allow the air to circulate properly The ambient...

Страница 23: ...them with cold water Ensure that the filters are dried completely dry in the shade before putting them back into the unit The activated carbon filters where fitted can be reactivated by placing in dir...

Страница 24: ...the product ensure that is done safely and in accordance with local by laws and reulations In order to do so follow the steps described in the installation manual in reverse order and use the necessa...

Страница 25: ...r Vaillant si riserva il diritto di apportare modifiche senza preavviso Vaillant pridr ava pravo na izmjene bez najave Vaillant reserves the right to add modifications without prior notice Vaillant be...

Страница 26: ...illant hr Vaillant S p A 20159 Milano Via Benigno Crespi 70 Telefono 02 69 21 71 Telefax 02 69 71 22 00 www vaillant it info italia vaillant de Vaillant Ltd Nottingham Road Belper Derbyshire DE56 1JT...

Отзывы: