4 Operation

8

Instructions for use auroFLOW plus 0020160592_00

Note

You always have the option to cancel the change
to a setting or the reading of a value by pressing
the left-hand selection button.

Menu
Live Monitor

Information

Basic settings

Select

Back

A highlighted object is indicated in the display inversely (light
text on dark background).

Note

If you do not press any buttons for more than 15
minutes, the display returns to the basic display.
Any unconfirmed changes are then cancelled by
the product.

4.3

Basic display

0

25°C

In the normal operating condition, the basic display is shown.
The basic display shows the current condition of the solar
system. When the left-hand selection button is pressed, the
display shows the solar yield. If the display is dimmed, the
first button push switches on the display illumination. In this
case, to trigger the button function, you must press the but-
ton again.

You can switch back to the basic display by:

pressing

to exit the selection levels

not pressing any button for longer than 15 minutes.

The product does not save any unconfirmed changes in this
case.

If there is a fault message, the basic display switches to a
plain text display of the fault message.

4.4

Operating levels

The product has two operating levels.

4.4.1

Operating level

The standard operating level offers you the most frequently
used setting options that do not require any special prior
knowledge and displays the most important information.

You can access additional information using a menu.

4.4.2

Installer level

The installer level must only be operated by a competent
person. The installer level is therefore protected with a code.
The competent person uses this level to calibrate the para-
meters of the solar charger with the solar system.

4.5

Reading the solar yield

Previous day

0 kWh

Solar yield

Back

Next

The solar yield can be displayed in the basic display in kilo-
watt hours as follows:

Press

.

The display shows the solar yield from the previous
day.

Press

.

The display shows the solar yield from the current
month.

Press

.

The display shows the solar yield from the current
year.

Press

.

The display shows the total solar yield.

Содержание auroFLOW plus

Страница 1: ...tructions for use auroFLOW plus Solar system GB IE Instructions for use Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Telefon 021 91 18 0 Telefax 021 91 18 28 10 info vaillant de www vaillant de ...

Страница 2: ...sic display 8 4 4 Operating levels 8 4 5 Reading the solar yield 8 5 Troubleshooting 9 5 1 Reading fault messages 9 6 Auxiliary functions 9 6 1 Operation in the menu 9 6 2 Live Monitor 12 6 3 Displaying contact data 12 6 4 Displaying the serial number and article number 12 6 5 Displaying operating hours 12 6 6 Setting the language 12 6 7 Setting the date time and summer time 12 6 8 Setting the dis...

Страница 3: ...ing water may cause damage to the building structure If there is a possibility of leaks in the pipework close the service valves immediately Have any leaks remedied by a heating specialist com pany 1 3 CE label The CE label shows that the products comply with the basic requirements of the applicable guidelines as stated on the identification plate 1 4 Intended use There is a risk of injury or deat...

Страница 4: ...erators are used in solar sup ported heating installations e g heat pumps block heating and generating plants and gas boilers The hot water gener ation can be combined with the buffer cylinder The auroFLOW plus solar system comprises Collector field auroFLOW plus solar charger Buffer cylinder Solar lines Heating water pipes In addition a system controller can be used to control all components of t...

Страница 5: ...at the solar system functions correctly The fluid capacity of the collector field and the solar lines is precisely designed with the solar system in mind The minimum length and the maximum length of the solar lines must be observed All solar lines have defined diameters in relation to the number of collectors The use of corrugated hoses impairs the functionality of the solar system The design and ...

Страница 6: ...is pumped further by the solar pump When the solar system heats up the solar fluid and the air expand The pressure of the air enclosed in the solar sys tem increases slightly as a result The enclosed air in the system therefore fulfils the role of an expansion vessel The increased pressure is necessary and must not be discharged in any way For this reason an air vent must not be fitted in the sola...

Страница 7: ...perature sensor T5 Symbol Meaning Explanation Solar pump s active Flashes Solar circuit is starting up filling of the field Permanently on solar circuit running cylinder charging pump active F XX Fault in the solar system Appears instead of the basic display A plain text display explains the displayed fault code 4 2 Operating concept The product is operated using the selection buttons and the plus...

Страница 8: ...lection levels not pressing any button for longer than 15 minutes The product does not save any unconfirmed changes in this case If there is a fault message the basic display switches to a plain text display of the fault message 4 4 Operating levels The product has two operating levels 4 4 1 Operating level The standard operating level offers you the most frequently used setting options that do no...

Страница 9: ...r 1272 Electronics fault in cylinder charge pump 1273 Electronics fault in solar pump 1274 Electronics fault in solar pump 2 1275 Cylinder charge pump blocked 1276 Solar pump blocked 1277 Solar pump 2 blocked 1278 T5 collector sensor fault 1279 T6 cylinder temperature sensor fault 1281 T1 temperature sensor fault 1282 T2 temperature sensor fault 1283 T3 temperature sensor fault 1284 T4 temperature...

Страница 10: ...urs Select Back Information Contact data Serial number Operating hours Select Back Information Contact data Serial number Operating hours Select Back Contact data Back Serial number Back Operating hours Back Cylinder charge pump S xx Next Collector temperature Back 20 C Next Cylinder temperature Back 40 C Next Power Back Cylinder circuit 0 kW 50 Menu Solar yield Live Monitor Information Select Bac...

Страница 11: ...ate Select Back Language Back 02 English Language Cancel 02 English OK Cancel English OK Basic settings Language Display contrast Date Select Back Basic settings Language Display contrast Date Select Back Basic settings Display contrast Date Time Select Back Basic settings Date Time Summer winter time Select Back Display contrast Back 255 Date Back 05 05 12 Time Back 10 00 Summer winter time Back ...

Страница 12: ...s using the menu point mentioned above 6 7 Setting the date time and summer time Note The date time and automatic summer winter ad justment can only be set if there is no system con troller connected Menu Basic setting Date You can use this menu point to set the date Menu Basic setting Time You can use this menu point to set the time Menu Basic setting Summer winter time You can use this menu poin...

Страница 13: ...e disposal company Dispose of packaging that cannot be cleaned in the same way as solar fluid Uncontaminated packaging can be reused 9 Customer service and guarantee 9 1 Customer service To ensure regular servicing it is strongly recommended that arrangements are made for a Maintenance Agreement Please contact Vaillant Service Solutions 0870 6060 777 for further details 9 2 Guarantee Vaillant prov...

Страница 14: ... 13 Solar fluid 13 Documents 4 F Fault 9 Fault message 9 H Heating installation Leaking 3 I Inspection 3 Installation 3 Instructions Applicability 4 L Live Monitor 12 M Maintenance 3 12 Menu Design 9 Overview 10 O Operating hours Cylinder charging pump 12 Operating level Competent person 8 Operator 8 Operator control elements 7 P Packaging Disposal 13 Product status 12 R Repair 3 S Serial number 1...

Страница 15: ......

Страница 16: ...ns 080 70 606 07 77 info vaillant co uk www vaillant co uk Vaillant GmbH 2012 These instructions or extracts thereof may only be printed with the written consent of Vaillant GmbH All designations of products in these instructions are brand names trade marks of the companies in question We reserve the right to make technical changes ...

Отзывы: