Detecting and eliminating faults 6
0020214277_01 atmoTEC exclusive, atmoTEC plus Operating instructions
13
6
Detecting and eliminating faults
▶
If faults or fault messages (
F.XX
) occur, proceed in ac-
cordance with the table in the appendix.
▶
If the product is not functioning correctly, contact a com-
petent person.
7
Care and maintenance
7.1
Maintenance
Annual inspection and maintenance of the product by a com-
petent person is required to ensure that the product is per-
manently ready and safe for operation, reliable, and has a
long service life.
7.2
Caring for the product
▶
Clean the casing with a damp cloth and a little solvent-
free soap.
▶
Do not use sprays, scouring agents, detergents, solvents
or cleaning agents that contain chlorine.
8
Decommissioning
8.1
Temporarily decommissioning the product
Caution.
Risk of material damage due to frost
The frost protection and monitoring devices
are only active while the unit is connected
to the power grid, the product is switched on
via the main switch and the gas stopcock is
open.
▶
You must use the control if you want to
activate and deactivate the product in
normal mode.
▶
If no control is present when a main switch
has been switched on, set the rotary
knobs for the target heating flow and
cylinder values to the anti-clockwise end
stop.
▶
Do not disconnect the product from the
power grid when it is in normal mode.
▶
Leave the main switch in position 1 in
normal mode.
E
bar
3
2
1
1
Main switch
2
Heating flow temperat-
ure rotary knob
3
Domestic hot water
rotary knob
1.
Turn the domestic hot water rotary knob
(3)
anti-clock-
wise as far as it will go.
2.
Turn the rotary knob for the heating flow temperature
(2)
anti-clockwise as far as it will go.
3.
Turn the main switch
(1)
to position
0
.
4.
Close the gas stopcock and the cold-water isolation
valve.
–
The isolators are not included in the scope of deliv-
ery for your product. They are installed on-site by
the competent person. Ask the competent person
to explain where the isolators are located and how
they are operated.
8.1.1
Preventing frost damage
The product is equipped with a frost protection function.
If the heating flow temperature falls below 8 °C when the
main switch is switched on, the product's pump starts up.
If the heating flow temperature falls below 5 °C when the
main switch is switched on, the product starts up and heats
the circulating water on both the heating side and the hot-
water side (if available) to approx. 30 °C.
Caution.
Risk of material damage due to frost.
The frost protection function cannot guaran-
tee flow through the entire heating installa-
tion, which means that parts of the heating
installation may freeze and therefore become
damaged.
▶
During a period of frost, ensure that the
heating installation remains in operation
and that all rooms are sufficiently heated,
even when you are away.
▶
Consult a competent person about this.
8.1.2
Draining the heating installation
Another way to protect the heating installation and the
product from frost for very long switch-off periods is to drain
them completely.
▶
Consult a competent person about this.