Operation 4
0020214277_01 atmoTEC exclusive, atmoTEC plus Operating instructions
11
▶
Have a competent person inform you
about the measures that should be
taken to protect against Legionella in
your installation.
▶
Do not set any water temperatures
below 60 °C without consulting the
competent person first.
▶
Set the required cylinder temperature on the control.
Conditions
: No control connected
E
bar
1
2
Danger!
Risk of death from legionella.
Legionella multiply at temperatures below
60 °C.
▶
Have a competent person inform you
about the measures that should be
taken to protect against Legionella in
your installation.
▶
Do not set any water temperatures
below 60 °C without consulting the
competent person first.
▶
Set the domestic hot water rotary knob
(1)
to the re-
quired cylinder temperature.
–
The required temperature is shown in the display
(2)
. After three seconds, this display goes out and
the default display reappears (current heating flow
temperature)
4.10.2 Switching on the warm start function
Applicability:
atmoTEC exclusive, Product with integrated domestic hot
water generation
b
a
1
▶
To switch on the warm start function, turn the do-
mestic hot water rotary knob
(1)
clockwise as far as it
will go (setting
(a)
).
▶
Set the rotary knob to the required domestic hot water
temperature (e.g. setting
(b)
).
–
The keep-warm temperature is automatically ad-
justed to the set domestic hot water temperature.
The heated water is then immediately available
when you draw it off. The
symbol flashes in the
display.
Applicability:
atmoTEC plus, Product with integrated domestic hot water
generation
b
a
1
▶
To switch on the warm start function, turn the do-
mestic hot water rotary knob
(1)
clockwise as far as it
will go (setting
(a)
).
–
The keep-warm temperature is automatically ad-
justed to the set domestic hot water temperature.
The heated water is then immediately available
when you draw it off. The
symbol flashes in the
display.
4.10.3 Switching off the warm start function
Applicability:
atmoTEC exclusive, Product with integrated domestic hot
water generation
b
c
1
▶
To switch off the warm start function, turn the do-
mestic hot water rotary knob
(1)
anti-clockwise as far
as it will go (setting
(c)
).
–
The symbol goes out.
▶
Set the rotary knob to the required domestic hot water
outlet temperature (e.g. setting
(b)
).
Applicability:
atmoTEC plus, Product with integrated domestic hot water
generation
b
c
1
▶
To switch off the warm start function, turn the do-
mestic hot water rotary knob
(1)
anti-clockwise as far
as it will go (setting
(c)
).