Appendix
0020273765_00 atmoMAG Installation and maintenance instructions
23
#
Maintenance work
Interval
4
Cleaning the burner
If required, at least every
2 years
14
5
Cleaning the heat exchanger
If required, at least every
2 years
16
6
Cleaning the injector rail
If required, at least every
2 years
14
7
Cleaning the down-draught diverter
If required, at least every
2 years
15
8
Check the ignition electrode and thermocouple for damage, and replace
any bent and damaged components
Annually
9
Checking the seals on the test nipples for damage and replacing any
damaged seals
Annually
10
Checking that the water flow switch (micro switch) is working correctly
Annually
11
Carry out a test operation on the product, incl. domestic hot water gener-
ation
Annually
12
Checking leak-tightness
Annually
13
13
Checking the heat input
Annually
16
14
Check the flame pattern. Flames must not touch the heat exchanger shaft
If required, at least every
2 years
15
Visually inspecting the test nipples and hoses
Annually
16
Interrupt the thermocurrent by disconnecting the connection between the
thermocouple and holding magnet. The product must be shut down
Annually
17
Checking the water valve
If required, at least every
2 years
16
18
Logging flue-gas measured values and any maintenance work that was
carried out
Annually
19
Checking the product to see if flue gas is escaping at the down-draught
diverter, with the doors and windows closed and the casing installed
Annually
F
Technical data
Technical data
–
General
MAG mini 114/1 I(P-
INT)
Designated country (designation
in accordance with ISO 3166)
AT, DE
Approved gas boiler category
I
3P
Unit dimensions, height
580 mm
Unit dimensions, width
310 mm
Unit dimensions, depth (incl.
rotary switch)
255 mm
Flue pipe connection diameter
110 mm
Min. length of the flue pipe
0.5 m
Gas connection diameter
1/2
″
conical
Water connection diameter (inlet)
G1/2"
Water connection diameter (outlet)
G1/2"
Net weight
9.6 kg
Gross weight
12.1 kg
Test symbol/registration no.
1008CS3137