3 Operation

Instructions for use VUI 362-7

8

3.4.2 Setting the external controls 

• Set the room thermostat (3, accessory) and/or the

thermostatic radiator valves (4, accessory) according
to the instructions supplied with the control(s).

Note!

Vaillant offer room thermostat/ time control
accessories which give accurate and economic
room temperature control as well as improved
comfort.
Ask your installer!

The boiler will now operate automatically to provide
central heating for the conditions selected on the
external controls and also provide domestic hot water
on demand).
Whilst the boiler is operating, the boiler display (7, fig.
3.2) indicates the temperature of the water within the
boiler circuit. After the boiler stops operating the pump
and fan will continue to operate for a short period to
fully disperse the heat from the boiler.

Note!

The boiler incorporates an anti-cycling
economiser control to prevent energy wasteful
ON and OFF operation of the boiler for short
periods when in the central heating mode. When
turning the room thermostat to a higher setting
there may therefore be a short delay before the
boiler operates.

Fig. 3.9: Setting the external controller 

3

4

3.4 Heating operation

3.4.1 Setting the maximum radiator temperature

control 

• Turn the main switch (1) to the "l" position.
• Set the maximum radiator temperature control to the

desired setting using the control knob (2). We
recommend the following settings:

- Left setting during spring and autumn (turning the

control knob all the way to the very left switches OFF
heating),

- Middle setting during mild winter,
- Right setting during cold winter.

Fig. 3.8: Setting the flow temperature

VRC-VC

C

o

0

I

C

o

1

2

C

o

C

o

C

o

834641_12GB_032005.qxd  09.03.2005 16:42 Uhr  Seite 8

Содержание aquaPLUS VUI 362-7

Страница 1: ...VUI 362 7 For the user GB Instructions for use aquaPLUS Gas fired room sealed fan assisted combination boiler with 15L store...

Страница 2: ...n the service valves 6 3 2 2 Check the water contents 6 3 3 Domestic hot water operation 6 3 3 1 Warmstart operation 7 3 3 2 Obtaining hot water 7 3 4 Heating operation 8 3 4 1 Setting the maximum rad...

Страница 3: ...Both should be recorded in the Benchmark gas boiler commissioning checklist You can check your installer by calling CORGI direct on 01256 372300 01256 372300 1 4 EC designation The purpose of EC desi...

Страница 4: ...or suspect a gas leak Turn off the boiler Do not switch the light or any electrical switches in the hazardous area on or off do not use the telephone in the hazardous area avoid sparking such as ligh...

Страница 5: ...g 50 C or Displaying of a status error code 8 Correct burner operation normal flame or lock out crossed out flame Fig 3 2 Display indications 0 I C o C o VRC VC 1 2 3 7 6 5 4 8 3 Operation 3 1 Overwie...

Страница 6: ...et the control knob above the mid 12 o clock position to prevent excessive scale formation fig 3 5 VRC VC C o 0 I C o 1 3 2 Initial checks before turning ON 3 2 1 Open the service valves Ensure the co...

Страница 7: ...play Reset the hot water temperature control knob to the desired setting Note Irrespective of whether the warmstart facility is switched on or off the boiler will automatically operate to provide hot...

Страница 8: ...nd fan will continue to operate for a short period to fully disperse the heat from the boiler Note The boiler incorporates an anti cycling economiser control to prevent energy wasteful ON and OFF oper...

Страница 9: ...inguished during operation A new attempt to ignite the flame can then only be performed after pressing the Reset button Press the Reset button 2 and hold for approx 1 second Warning If the boiler stil...

Страница 10: ...e VRC VC C o 0 I C o C o C o C o 1 Fig 3 12 Reset 3 6 1 Faults in the hot water system To protect the storage vessel feed pump the appliance is equipped with dry running protection This prevents opera...

Страница 11: ...VC C o 0 I C o C o C o I 0 2 If the boiler is not operated for several hours during very cold weather there is therefore the possibility of the system freezing Please ensure that if you are absent dur...

Страница 12: ...834641_12GB 03 2005 Subject to alteration...

Отзывы: