8
Installation manual VER 0020064153_01
10 Technical
data
Unit
VER 75/4
VER 100/4
VER 150/4
VER 200/4
VER 240/4
Voltage
V
1/N/PE ~ 230 V
1/N/PE ~ 230 V
1/N/PE ~ 230 V
1/N/PE ~ 230 V
1/N/PE ~ 230 V
Connection value
kW
0.75
1.0
1.5
2.0
2.4
Frost protection
°C
approx. 4°C
approx. 4°C
approx. 4°C
approx. 4°C
approx. 4°C
Connection cable
1 m connection cable with mains plug
1 m connection
cable
Level of protection
Water splash protection IP 24, protection class II
corresponds to the directive on low voltages and EMC (electromagnetic compatibility)
Dimensions
(height x width x depth)
mm
430 x 340 x 85
430 x 420 x 85
430 x 580 x 85
430 x 740 x 85
430 x 900 x 85
Weight
kg
3.2
3.8
4.9
6.3
7.3
Table 10.1 Technical data