Set-up 4
0020271929_00 atmoMAG Installation and maintenance instructions
7
Applicability:
MAG 144/1 G(E-BE)
OR MAG 144/1 G(H-AT)
OR MAG 144/1 G(H-DE/CH)
OR MAG 144/1 G(LL-DE)
OR MAG 144/1 G(P-BE)
OR MAG 144/1 G(P-CH)
1
2
3
4
6
7
8
9
10
12
11
5
1
Down-draught diverter
2
Flue gas sensor
3
Heat exchanger
4
Burner
5
Generator
6
Flow rate se-
lector/temperature
selector
7
Gas valve assembly
8
Rotary power switch
9
Main switch
10
Electronics box
11
Ignition electrode
12
Monitoring electrode
3.3
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
4
Set-up
4.1
Checking the scope of delivery
1.
Remove the product from its box.
2.
Check that the scope of delivery is complete and intact.
4.1.1
Scope of delivery
Num-
ber
Designation
1
Gas-fired instantaneous water heater
1
Connection accessories that are included
1
Enclosed documentation
4.2
Wall pre-installation
60
60
a
3
1
2
Flush mounting
60
60
c
b
3
1
2
Surface installation
▶
Install the connections as follows:
–
1 = Cold water connection R 1/2
–
2 = Gas connection
–
3 = R 1/2 hot water connection
▶
Observe the following clearances for all product types:
–
a = 92 mm
–
b = 85 mm
–
c
≈
100 mm without thermal isolator device
–
c
≈
145 mm with thermal isolator device