Appendix
28
Installation and maintenance instructions atmoMAG 0020271929_00
MAG 114/1 G(LL-
DE)
MAG 114/1 G(E-
BE/FR)
MAG 114/1 G(H-
DACH)
MAG 114/1 G(LL-
DE)
Min. heat input (Q
min.
)
7.6 kW
7.6 kW
7.6 kW
7.6 kW
Max. heat output (P
max.
)
18.1 kW
18.1 kW
18.1 kW
18.1 kW
Min. heat output (P
min.
)
6.4 kW
6.4 kW
6.4 kW
6.4 kW
Control range
6.4 … 18.1 kW
6.4 … 18.1 kW
6.4 … 18.1 kW
6.4 … 18.1 kW
Max. permissible water pressure
P
w max.
1.3 MPa
(13.0 bar)
1.3 MPa
(13.0 bar)
1.3 MPa
(13.0 bar)
1.3 MPa
(13.0 bar)
Min. permissible water pressure P
w min.
when the temperature selector is po-
sitioned at "warm"
63 kPa
(630 mbar)
63 kPa
(630 mbar)
63 kPa
(630 mbar)
63 kPa
(630 mbar)
Min. permissible water pressure P
w min.
when the temperature selector is po-
sitioned at "hot"
41 kPa
(410 mbar)
41 kPa
(410 mbar)
41 kPa
(410 mbar)
41 kPa
(410 mbar)
Flue gas temperature at max. heat
output
200
℃
200
℃
200
℃
200
℃
Flue gas temperature at min. heat out-
put
105
℃
105
℃
105
℃
105
℃
Min. chimney draught
1.5 Pa
1.5 Pa
1.5 Pa
1.5 Pa
Min. chimney draught when using a
thermal flue non-return flap
10.0 Pa
10.0 Pa
10.0 Pa
10.0 Pa
MAG 114/1 G(P-
BE/FR)
MAG 114/1 G(P-CH)
MAG 144/1 G(E-BE)
MAG 144/1 G(H-AT)
Domestic hot water volume at the
"hot" temperature selector position
2.6 … 5.5 l/min
2.6 … 5.5 l/min
3.4 … 7 l/min
3.4 … 7 l/min
Domestic hot water volume at the
"warm" temperature selector position
5.4 … 11.0 l/min
5.4 … 11.0 l/min
6.5 … 14.0 l/min
6.5 … 14.0 l/min
Max. heat input (in relation to the net
calorific value H
i
)
21.7 kW
21.7 kW
27.7 kW
27.7 kW
Min. heat input (Q
min.
)
7.6 kW
7.6 kW
9.7 kW
9.7 kW
Max. heat output (P
max.
)
18.1 kW
18.1 kW
23.1 kW
23.1 kW
Min. heat output (P
min.
)
6.4 kW
6.4 kW
8.3 kW
8.3 kW
Control range
6.4 … 18.1 kW
6.4 … 18.1 kW
8.3 … 23.1 kW
8.3 … 23.1 kW
Max. permissible water pressure
P
w max.
1.3 MPa
(13.0 bar)
1.3 MPa
(13.0 bar)
1.3 MPa
(13.0 bar)
1.3 MPa
(13.0 bar)
Min. permissible water pressure P
w min.
when the temperature selector is po-
sitioned at "warm"
63 kPa
(630 mbar)
63 kPa
(630 mbar)
78 kPa
(780 mbar)
78 kPa
(780 mbar)
Min. permissible water pressure P
w min.
when the temperature selector is po-
sitioned at "hot"
41 kPa
(410 mbar)
41 kPa
(410 mbar)
49 kPa
(490 mbar)
49 kPa
(490 mbar)
Flue gas temperature at max. heat
output
200
℃
200
℃
185
℃
185
℃
Flue gas temperature at min. heat out-
put
105
℃
105
℃
90
℃
90
℃
Min. chimney draught
1.5 Pa
1.5 Pa
1.5 Pa
1.5 Pa
Min. chimney draught when using a
thermal flue non-return flap
10.0 Pa
10.0 Pa
10.0 Pa
10.0 Pa
MAG 144/1 G(H-
DE/CH)
MAG 144/1 G(LL-
DE)
MAG 144/1 G(P-BE)
MAG 144/1 G(P-CH)
Domestic hot water volume at the
"hot" temperature selector position
3.4 … 7 l/min
3.4 … 7 l/min
3.4 … 7 l/min
3.4 … 7 l/min
Domestic hot water volume at the
"warm" temperature selector position
6.5 … 14.0 l/min
6.5 … 14.0 l/min
6.5 … 14.0 l/min
6.5 … 14.0 l/min
Max. heat input (in relation to the net
calorific value H
i
)
27.7 kW
27.7 kW
27.7 kW
27.7 kW
Min. heat input (Q
min.
)
9.7 kW
9.7 kW
9.7 kW
9.7 kW
Max. heat output (P
max.
)
23.1 kW
23.1 kW
23.1 kW
23.1 kW