CONFIGURATION/PARAMETERIZATION
75
Parameter: “Status links”
10 different configurations can be created here. Depending on different IO configurations, several status mes
-
sages can be generated by using the status links.
* No entry “-” means that no entry has to be made.
** No entry “-” means that the value 0 is used (connection until OUT1).
*** The STO parameter will visible after activating the STO functionality.
Parameter
Selection
Description
E1 ... E12
-/0/1*
0 ... input is queried on LOW, 1 ... input is queried on HIGH; if
no entry is made, then the input status for this link does not
matter.
ON/OFF
-/0/1*
HW+
-/0/1*
HW-
-/0/1*
Anti valence
-/0/1*
Anti valence test
Item
-/0/1*
Positioning: 0 ... inactive, 1 ... active
Connection
-/0/1**
Status link: 0 ... not active, 1 ... active
STO***
-/0/1*
0 ... STO status is queried for inactive
1 ... STO status is queried for active
- ... STO status fo this link is not relevant
RM
-/0/ 1 ... 3**
Feedback: 1 ... 3 Number of from feedback signal (see “error
links”)
Error
-/0/1**
Error: 1 ... Error message will be generated
Hold reset
-/0/1**
1 ... Reset holding function (see “IO links”)
OUT1
-/0/1**
1 ... Digital output will be switched
Delays
Delay status link 1 ...
10
0 ... 65000ms
Deceleration time after which the parametrized status mes
-
sage (1 ... 10) occurs