CONFIGURATION/PARAMETERIZATION
63
Parameter: MC 8/10M (IR remote control)
WARNING!
Danger due to switched off limit switches
Accidents, severe injuries as well as property damages
►
No limit switches are active in the infrared manual mode (except if it was set in
advance)!
►
The IR manual mode will be deactivated by actuating the ON/OFF switch on the
control system.
Parameter
Selection
Description
MC 8/10M (IR remote
control)
Check box
Activate if a remote control is used.
Manual mode activa
-
tion mode
Via M/A button
The control system will be switched into manual mode using
the button [MAN].
Via M/A
CODE
The control system will be switched into manual mode using
the button [MAN] and subsequent code input (vehicle num
-
ber).
Save manual mode
zero voltage proof
Active
Behavior if voltage returns:
Active: Control system remains in IR manual mode
Inactive: Control system switches into automatic mode
Inactive