CONFIGURATION/PARAMETERIZATION
73
Parameter: “Stop sensor”
Parameter
Selection
Description
Stop sensor
Check box
Activate if a stop sensor is used (e.g. Senso-Part)
Fast switch of dis
-
tance
0 ... 10000mm
The drive will be stopped if the measured distance is smaller
than the adjusted value.
Near range distance 0 ... 10000mm
Distance in the near range
Fernbereichsdistanz1 0 ... 10000mm
Stop distance in the far range 1
Fernbereichsdistanz2 0 ... 10000mm
Stop distance in the far range 2
Remaining distance
in buffer speed be
-
fore reaching the stop
position
0 ... 1000mm
Distance after which the buffer speed will be used.
Buffer speed
0 ... 1200Hz/10
Buffer speed
Limiting distance af
-
ter identifying an ob
-
ject
0 ... 20000mm
Distance after which the speed limitation is active.
Speed limitation after
reaching the limit dis
-
tance
0 ... 120Hz
Maximum driving speed for active speed limitation.
Deceleration ramp
speed limitation after
reaching the limit dis
-
tance
0 ... 255 Hz/s
-
Delay collision protec
-
tion function near
range
0 ... 255 Hz/s
Deceleration ramp collision protection in near range
Deceleration colli
-
sion protection func
-
tion far range 1
0 ... 255 Hz/s
Deceleration ramp collision protection in far range 1
Deceleration colli
-
sion protection func
-
tion far range 2
0 ... 255 Hz/s
Deceleration ramp collision protection in far range 2
Restart the delay af
-
ter exceeding the re
-
starting hysteresis
0 ... 65000ms
Restart delay time
Restart hysteresis
0 ... 20000mm
Restart hysteresis