0000137936
rev. 6.1
3
•
Type__PROP
(Adjust value between OFF, PROP, ON/OFF or TIMED)
(only if set to Timed there are two new entries to make dosage cycles ON /
OFF selectable)
o
Timed ON
(Change the value from 5 to 3600 seconds)
o
Timed OFF
(Change the value from 5 to 3600 seconds)
§
Chlorine_Measure
(only if enabled)
•
Setpoint___1.2_ppm
(Adjust value with enter and up or down key) It’s
possible to adjust from 0.0 to 5.0 ppm
•
sp_type___low
(Adjust value LOW or HIGH)
•
ofa_time_000_min
(Change the value from 1 to 240 minutes or Off)
•
AlrBand__1.0ppm
(Adjust value from 0.0 to 5.0 ppm)
•
Type__PROP
(Adjust value between OFF, PROP, ON/OFF or TIMED)
(only if set to Timed there are two new entries to make dosage cycles ON /
OFF selectable)
o
Timed ON
(Change the value from 5 to 3600 seconds)
o
Timed OFF
(Change the value from 5 to 3600 seconds)
§
Flow rate meas.
(only if is present)
•
sensor_K Factor
(Select the sensor type with enter and up or down
key) It’s possible to select K Factor of W. Meter (Water Meter). Once the
type of sensor will be changed the system will ask for a reset of the
resettable totalizer and a new start date for the counter.
•
K factor___1.00
/
W.Meter__1
I
/ 1L
(This screen depend from the
type of sensor selected in the menu item before) For K Factor sensor:
Adjust value from 0.01 to 99999,99. For W. Meter sensor the value is in
pulses/liter; adjust value between I=0÷999 L=0÷999. If the sensor is
calibrated in this menu (K Factor and Water Meter), the string “Cal” appear
for a couple of seconds in place of the actual number, indicating that the
instrument will use the parameter recalculated based on the calibration.
•
Flow unit___L/s
(Change the measure unit between: liters per second
(L/s), liters per minute (L/m), cubic meters per hour (m
3
/h) and gallons per
minute (GPM))
•
Total unit___L
(Change the measure unit between: liters (L), cubic
meters (m
3
) and gallons (GAL))
•
Reset tr total
(Reset the resettable totalizer) After a confirmation
message, “ENTER to confirm”, will be asked to set the new start date for the
counter (dd/mmm/yyyy). If there is not date set in the screen with the Tr
totalizer value will be displayed “install”.
§
INPUT Flow
(Adjust value with enter and up or down key Enable or Disable)
•
It’s possible to enable(ON) or disable (OFF) signal input
§
Cal
(Calibration_probe)
(Adjust value with enter and up or down key)
§
Full
(pH 7 and 4, Redox 465 mV buffer solution)
§
Easy
(pH 7, Redox 465 mV buffer solution)
§
Off
(Disabled)
§
3 PUMP
*
(Third external pump management)
It’s possible to enable (ON) or
disable (OFF) the output for external pump
§
3P-TIME ON
(Adjust value from
00m01s to 59m59s
, it’s
the time which the third external pump output is active
)
§
3P-TIME OFF
(Adjust value from
00m01s to 59m59s
, it’s
the time which the third external pump output is off)