0000137936
rev. 6.1
4
§
Password
(Adjust value with enter and up or down key, standard value
0000
)
•
Save and escape Program setup with ESC key
§
Rele Func. Alr
*
(Adjust relay output: with: alarm or Redox measure)
§
P. ON Delay
*
(
This delay will only take effect if the system is turned off and
then on again by disconnecting its electrical power supply. The setting can be
disabled (Off - factory default) or else can be set to a delay time ranging from 1 to 60
minutes.)
§
Flow delay off
*
(is possible to set a delay on Flow Input activation or
reactivation (recirculation pump). The system waits before restarting the process.
The setting can be disabled (Off - factory default) or else can be set to a delay time
ranging from 1 to 60 minutes.
§
REED LOGic
(Adjust REED input: N.O. (normally open) or N.C. (normally
closed)
§
RESET CALIBRATION*
(To restore the default calibration parameters)
§
Reset CL
(Press Enter to select the reset (yes or no) and
confirm with Enter)
§
Reset ph
(Press Enter to select the reset (yes or no) and
confirm with Enter)
§
Reset rx
(Press Enter to select the reset (yes or no) and
confirm with Enter)
§
Reset FLoW
(Press Enter to select the reset (yes or no)
and confirm with Enter)
§
Reset all parameters*
(Press Enter to select the reset (yes or no) and
confirm with Enter, the system will restore the default parameters)
§
Control panel
(Input measures visualization pH=mV; Rx=mV; CL=μA;
Temperature=Ohm; FlowFreq=Hz; Date=dd/mmm/yyy) Switch between screens with
keys Up and Down.
o
Exit______save
(Adjust value with up or down key and confirm with enter key)
•
Priming Pump: Keep Press UP Key for 1 seconds to prime the first pump (on the left)
o
priming_____
•
Priming Pump: Keep Press Down Key for 1 seconds to prime the second pump (on the right)
o
priming_____
•
The unit doses in proportional mode respect at Set Point (minimum distance 25%, maximum
distance 90% of 10 minutes time period dosing)
Note
: The unit in program menu to go out in automatic mode after 1 minutes of wait time, the unit
doesn’t save nothing.
*
This menu item is present only for pH/Redox/Chlorine version.