10
VII.
Testing
1
1
1
1.
.
.
.
Inspection before use
A
.
Check installation of the whole machine and the pipe connections
according to the pipe connecting drawing;
B
.
Check the electric wiring according to the electric wiring diagram; and
earthing connection;
C
.
Make sure that the main machine power switch is off;
D
.
Check the temperature setting;
E
.
Check the air inlet and outlet.
2
2
2
2.
.
.
.
Trial
A
.
The user must “Start the Pump before the Machine, And Turn off the
Machine before the Pump”, or the machine will be damaged;
B
.
The user should start the pump, check for any leakage of water; and then
set suitable temperature in the thermostat, and then switch on power
supply;
C
.
In order to protect the swimming pool heater, the machine is equipped with
a time lag starting function, when starting the machine; the blower will
run 1 minute earlier than the compressor;
D
.
After the swimming pool heater starts up, check for any abnormal noise
from the machine.