background image

~11~

0606940

58090...

520/222413

580100006

580100009

5809593

580100008

Pipe bracket 47-51mm

Heat element

Clamp

Adaptor socket connection

Box of heating - in the middle

Box of heating - cover full

Pressure switch

Body stainless

Box of heating - cover =D 60mm

identifikace

popis

detail

1

2

3

4

5

6

7

8

9

Trubková svorka 47-51mm

Topná patrona nerez 3,6,9,12,15,18kW

Svorka WAGO třípolová 32A

Průchodka PG16 a PG11

Krabice na topení-střední díl

Krabice na topení-víčko plné

Tlakový spínač

Nerezové tělo

Krabice na topení-víčko =D 60mm

identifikace

popis

detail

0336110042

5809591

5809560

Převlečná matka

O-kroužek k převl.matce

Termostat 0-40st komplet

Tepelná pojistka

Šroubení 50mm stočené

Manžeta se závitem 2"ex

Compression nut

O-ring of compression nut

Thermostat 0-40st complete

Heat fuse

Unions connection

Flange adaptor 2"ex

10

11

12

13

14

15

Содержание EOV Series

Страница 1: ......

Страница 2: ...words The flow water heater of the EOV type is specially desig ned and constructed for heating of water in the outdoor or interi or swimming pools baths and vertiginous bath tubes Its activity is bas...

Страница 3: ...nt using an electric ther mostat for example Preparation for the assembly 1 Check the package content Immediately after delivery check the package and make sure that the supplied flow heater which was...

Страница 4: ...t clogging of heating unit by mechanical impurities and to prevent clogging of the whole circuit system The additional equipment should be installed in front of the heater within the filt ration circu...

Страница 5: ...r since in some cases the changes of pressure in piping or turbulences would occur This has a bad impact on the activity of the pressure switcher Under such condition the switching contactor would ope...

Страница 6: ...chloridu max 150 mg l obsah chloru max 1 mg l rozsah pH 7 0 7 8 A qualified electrician with ade quate certificate should connect the electric parts of the equip ment The heater must be conne cted ov...

Страница 7: ...ion montiert wird Das Produkt wurde von Elektro technischer Pr fanstalt bewilligt Z ru n podm nky z ruka na v robek je 24 m s c od data instalace v robku mus b t potvrzeno v z ru n m listu v The warra...

Страница 8: ...8 Obr 3 spr vn zapojen sm rem dol Figure 3 Correct connecting in the downward direction Bild Nr 3 richtige Einschaltung in Richtung nach unten 3 Obr 4 Figure 4 Bild Nr 4 4...

Страница 9: ...lectric heating TT heating unit Q current protector 30 mA FU F fuse TR regulating thermostat TP thermal fuse TS pressure flow switcher K1 contactor Bild Nr 5 Schaltungs und Anschlu schema des elektris...

Страница 10: ...CYSY CGSG Leistung des Heizk rpers Schutzschalter Anschlusskabel CYSY CGSG CYSY CGSG 3 kW 1 x 230 V 16 3c x 2 5 mm2 3 1 x 230 16 3c x 2 5 2 3 kW 3 x 230 V 10 4b x 1 5mm 2 5c x 1 5 mm2 3 3 x 230 10 4b...

Страница 11: ...51mm Topn patrona nerez 3 6 9 12 15 18kW Svorka WAGO t polov 32A Pr chodka PG16 a PG11 Krabice na topen st edn d l Krabice na topen v ko pln Tlakov sp na Nerezov t lo Krabice na topen v ko D 60mm ide...

Страница 12: ...12 Informace o tom kde je mo n elektroza zen zdarma odlo it z sk te u va eho prodejce na obci nebo na www elektrowin cz...

Отзывы: