6
3
Assembly and installation 81552
From below push the top part of the rubber seal up through the hole in the bath.
Push the waste housing up into the seal and hold in place.
From inside the bath place the waste flange over the seal and secure in position using
the screw, do not over tighten as might damage the bath.
Slide the compression nut, washer and seal over the pipe, push the pipe fully into the
waste assembly, slide along the seal and washer and finally screw on the nut, hand
tight only. Push in the plug.
Decreasing the pipe length.
The pipe can be shortened by carefully cutting, removing any burrs. Ensure all calculations
are correct before cutting the pipe. Finish by following the above procedure.
Plug adjustment
To adjust the opening and/or closing position of the plug.
With a flat screwdriver loosen the adjusting screw to the required position, tighten the
locking nut, and refit into the waste. Test, and readjust if necessary.
Plug
Seal
Locking nut
Adjusting screw
Waste screw
Waste flange
with seal
Seal
Compression
nut
Washer
Seal
Overflow/waste
assembly
Overflow pipe
Cable to pop up waste
Adjusting
screw
Locking nut
Operation
Turning the handle anti-clockwise closes the plug.
Turning the handle clockwise opens the plug.
Assembly and installation 81389
The length of the overflow pipe can be adjusted by pulling apart or pushing together
the inner and outer overflow pipes.
Should you need to reduce the length even more, pull the outer overflow out of the
collet, cut both the outer overflow pipe and the inner overflow pipe to the required
length, remove any burrs and reassembly.
Ensure all calculations are correct before cutting pipes.
Remove the blanking plug(s) from the overflow assembly. Using PTFE tape fit the inlet
elbow(s).
Push the rubber seal onto the overflow/waste assembly, and from the outside hold in
place over the bath overflow hole.
Screw on the overflow housing, tighten with an allen key.
Caution:
do not overtighten as this may damage the parts and/or the bath.
Place the overflow fascia over the overflow housing, make sure the slots for the outlet
and overflow are on the underside. Tighten by screwing the grubscrew located on the
underside of the overflow fascia.
Connect to the supply pipe work.
Overflow/waste
assembly
Rubber seal
Overflow fascia
Inner overflow pipe
Inlet elbow
Inlet elbow
Overflow
housing
Allen key
Allen key socket
Outlet and
overflow slots
Outer overflow pipe
Collet