VADDIO QUICK-CONNECT CCU Z700 Скачать руководство пользователя страница 8

Quick-Connect CCU Z700 

Quick-Connect CCU Z700 Installation and User Guide 341-718 Rev. B                                                                                  Page 8 of 12 

FCC, ICES-003 Compliance and CE Declaration of Conformity  

For Vaddio Quick-Connect CCU and EZIM CCU products 

 
 
 

FCC Part 15 Compliance 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his/her own expense. 

Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This 
device must accept any interference including interference that may cause undesired operation of the device. 

Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void 
the user’s authority to operate this equipment. 

 

ICES-003 Compliance 

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set 
out in the Radio Interference Regulations of the Canadian Department of Communications.   

Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux 
appareils numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par 
le ministère des Communications du Canada. 

 

 

European Compliance 

This product has been evaluated for Electromagnetic Compatibility under the standards for Emissions and 
Immunity and meets the requirements for E4 environment.  This product complies with Class A (E4 
environment). In a domestic environment this product may cause radio interference in which case the user 
may be required to take adequate measures. 

Standard(s) To Which Conformity Is Declared: 

 

EMC Directive

 89/336/EEC 

EN 55022A

  

 

Conducted and Radiated Emissions 

EN 55024 

 

Electromagnetic Compatibility - Immunity

 

EN 61000-4-2

    

Electrostatic Discharge Requirements 

EN 61000-4-3

    

Radiated Electromagnetic Field Requirement 

EN 61000-4-4

    

Electrical Fast Transients / Burst Requirements 

EN 61000-4-5 

    

Surge Requirements 

EN 61000-4-6

   

Conducted Immunity Requirements 

EN 61000-4-8

   

Power Frequency Magnetic Field Requirements 

EN 61000-4-11

   

Voltage Dips, Interrupts and Fluctuations Requirements 

 

Содержание QUICK-CONNECT CCU Z700

Страница 1: ...store settings on two discrete Scene buttons and buttons for Auto White Balance One Push White Balance and Auto Iris Like all Vaddio Quick Connect systems the Thin Profile Wall Mount and mounting hard...

Страница 2: ...for power to ensure the motors receive the required current to operate properly The Video Cat 5 cable uses all four pairs for video The RS 232 Cat 5 provides communication to the camera for CCU and PT...

Страница 3: ...stment scenes A B can be stored into microprocessor memory When lit backlit blue SPDT switch the scene is activated To store a scene the user adjusts the camera to taste and touches and holds the scen...

Страница 4: ...transmitted through a differential amplifier to a receiver at the EZIM CCU The G L gain adjustment is on the EZIM CCU or the receive side of the signal Camera Feature Switches The QCCU interface has...

Страница 5: ...timize the performance of the camera Pre wire all cabling as required see wiring diagram examples The Thin Profile Wall Mount for the Quick Connect CCU Z700 can be mounted directly to a 3 gang wall bo...

Страница 6: ...dard connectors The basic system connectivity is illustrated in Figure 2 Note Plugging the POWER CAT 5 Cable into the wrong RJ 45 may cause damage to the camera system and void the warranty COMPLETING...

Страница 7: ...ideo feed to camera EZIM Tally 2 Pin Phoenix type spring cage connector Video Inputs BNC Connector for Sync Video Outputs BNC Connectors for HD Analog Component Y PB PR SD Composite Video RJ 45 Transp...

Страница 8: ...e user s authority to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interfe...

Страница 9: ...d 3 Not Used 4 Not Used 5 Not Used 6 GND 7 RXD from TXD 8 TXD to RXD RS 232 G L OUT Connector RJ 45 Pin Signal RS 232 1 Not Used 2 Not Used 3 Not Used 4 G L 5 G L GND 6 GND 7 TXD to RXD 8 RXD from TXD...

Страница 10: ...BS GND 3 Y Y 4 C PB 5 C GND PB GND 6 Y GND Y GND 7 Not Used PR 8 Not Used PR DB 25 Connector Pins Signal 1 CVBS GND 14 CVBS 2 G L GND 15 G L 3 NC 16 GND IN 4 TXD IN 17 RXD IN 5 NC 18 NC 6 NC 19 NC 7 G...

Страница 11: ...s and describe the reason for repairs or returns as well as the date of purchase and proof of purchase Include your assigned RMA number in all correspondence with Vaddio Write your assigned RMA number...

Страница 12: ...63 971 4464 www vaddio com 2008 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing subject to change Vaddio Quick Connect H...

Отзывы: