Step 4:
Leave the IR out OFF (up) as default.
Step 5:
Use 9600bps for control speed as default.
If the camera is mounted inverted, then set the Image Flip to ON, otherwise leave it off.
The test bars
are really, really, totally non-standard (horizontal - just to mess with the old-timers) and will
override the video output. These test bars are 75% IRE. Use the test bars for…testing.
A Cautionary Note:
In the event that the rotary switch was moved from “
0
” and left on
“C” - RESET - RESTORES TO FACTORY DEFAULTS,
and is power cycled, all data
will be lost. Sometimes a RESET is required, but those occasions are generally few
and far between. On the web pages, a warning dialog box was added to inform the
administrator the state of the switch. If the factory reset is not desired, please move
the switch back to “
0
” and do not power cycle the camera. The warning looks almost
exactly like the warning below…
S
TEP BY
S
TEP
I
NSTRUCTIONS TO INSTALL THE
W
ALL
VIEW
HD-USB
SR
C
AMERA
S
YSTEM
Step 1: Locating the Camera
Locate the camera mounting position while paying close attention to camera
viewing angles, lighting conditions, possible line of site obstructions, and
checking for in-wall obstructions where the camera is to be mounted. Pick a
mounting location to optimize the performance of the camera.
Like all Vaddio WallVIEW systems, the WallVIEW HD-USB SR is easy to install
and operate. The product was specifically designed with CAT-5 cable
connectivity for the extension of power and an Active USB 2.0 Extension cable
that is powered by the computer’s USB port.
Step 2:
After determining the optimum location of the camera system, run a CAT-5 cable and the Active USB 2.0
Extension Cable from the computer location to the camera location. Make sure to mark and test the CAT-5 cable
and use real RJ-45 crimper and connectors using the 568B straight-through wiring standard. Please do not use
the “feed-thru” type RJ-45 connectors for professional installations.
Step 3:
Using the CONCEAL wall mount directions, install the CONCEAL mount. If mounting to the drywall with wall
anchors, use four (4) quality wall anchors. Make sure to level the mount and tighten the mounting screws.
Step 4:
Connect the CAT-5 cable to the EZ POWER VIDEO RJ-45 port on the back panel of the HD-USB camera.
Connect 1’ (305mm) USB 2.0 Cable Type-B Male into the USB Type-B Female on the back panel of the HD-USB
camera. Connect the Active USB Extension Cable’s Type-A Female to the 1’ (305mm) USB cable’s Type-A Male
Connector. Field dress the cabling and tuck it back into the CONCEAL mount and place on the back cover to
hide all the cabling.
NOTE: Check all Cat-5 cables for continuity in advance of the connection. Do not plug the Cat-5
cable into any other RJ-45 port but the EZ POWER VIDEO port. There is 24 VDC Volts on Pins 1 & 2.
Plugging into any other port may cause damage to the camera system and void the warranty.
Step 5: At the Head-End
Plug the Active USB Extension Cable Type-A Male directly into the computer. Plug the other end of the CAT-5
cable into the RJ-45 port of the Power Extension Module.