VLC Media Player Example: 

 
1)  Same first step as above. 

 

2)  Open VLC Media Player and perform the following steps: 

a.  Click on the Media menu and drop down to Open Capture Device and click it. 
b.  Under Device Name, go to the Video Device Name drop down and choose USB Video Device. 
c.  Under Options, enter the Video Size as 1280x720 
d.  Click on Play 
e.  From there, VLC needs some instruction on the aspect ratio, so click on Tools and drop down to 

Aspect Ratio and drop down again to 16:9 for 720p (1280x720). 

 
VLC is a powerful record/playback system and buffers the images so you will notice some delay in the way VLC 
displays the image.   
 
In General Terms…  
With all the compatible software available, in general terms, the video device, aspect ratio, and resolution may 
need to be set manually the first time through initial set-up.  Some systems are easier than others (like Skype) 
and others are more technical in nature and tend to do more stuff.   

 

T

ECHNICAL 

S

PECIFICATIONS

Part Numbers  

999-6990-000 North America, 999-6990-001 International

Video Outputs 

 

USB 2.0 (MJPEG) 

o

 

Resolution up to 720p/30 USB 2.0 (MJPEG)  

o

 

Use “HD VIDEO AND USB 2.0 VIDEO SELECT” rotary positions 0, 1, 4 & 5 for USB.2.0 Video 
only 

 

H.264 (IP) - Release 2.0 

o

 

Resolution up to 1080p/30 (H.264 over IP & USB 2.0 - Release 2.0) 

 

Analog Component (YPbPr), 

o

 

Analog resolutions up to and including 1080p/60 (YPbPr) 

 

CVBS - Analog only 

o

 

480i and 576i (4:3, LB and SQ) 

USB Interface 

Connector:  Type-B, USB 2.0 Compliant, Supported Drivers:  Standard UVC device (no custom drivers) 

Network Interface 

Connector:  RJ-45, 10/100 Base-T, Supported Protocols:  RTSP Streaming, HLS Streaming (apple’s variant 
of HTTP streaming) - Release 2 

H.264 Resolutions 
(Release 2.0.0) 

CIF, 640x480 (VGA), 576p, 720p/30 1080p/30 (1080p Ethernet H.264 only) 

User Control 

Vaddio IR Remote Commander, On Screen Display for camera set-up, RS-232, Ethernet (web page)  

Supported Media Players 

Apple Quick-Time, VLC Media Player and Reel Player 

Supported Browsers 

Internet Explorer 8 & 9, Safari 4 &5, Safari/iOS, Chrome, Firefox 

Image Sensor 

1/3-Type Exmor High-speed,  
Progressive Scan CMOS Sensor with 1.3 Megapixels 

Minimum Illumination 

0.7 LUX (F1.6, 50IRE) 

Lens/ Focal Length 

19X Optical Zoom, F=4.5mm wide to 85mm tele (F1.6-F2.9),  
Min. Focus Distance 1.0m 

Horizontal Viewing Angle 

58.1° Wide End to 3.2°  
Tele End - 16:9 Format  

Pan Range 

Pan:  +170 degrees to -170 degrees, Tilt:   
+90 degrees to -30 degrees,  
Invertible for Ceiling Mount  

Preset Positions 

16 (internal), 6 recalled via IR Remote 

General Information 

 

Operating Temperature 

32° to 104° F (0° to 40° C) / 20% to 80% Relative Humidity 

Dimensions / Weight 

7.81” (198.37mm) H x 6.67” (169.42mm) W x 7.057” (179.25. mm) D / 6.04 lbs. (2.7397kg.) 

Software Release 
Information 

Release 1.0.0:

  Includes USB 2.0 Outputs and Analog Outputs simultaneously on and ready to use.  Ethernet 

control via an internal web page and upgrading software capability is active. 

Release 1.2.0:

  Improvements, additions to functionality, Telnet control, UC client compatibility and UVC 

resolutions. 

Future Release 2.0.0:

  H.264 Streaming will be activated for Ethernet port. 

 
 

Содержание ClearVIEW 999-6990-000

Страница 1: ...onferencing Camera Document Number 342 0437 Rev B Camera Software Revision 1 2 0 ClearVIEW HD USB PTZ USB H 264 and Analog HD Pan Tilt Zoom Conferencing Camera Part Numbers 999 6990 000 North America...

Страница 2: ...ity for Release 2 0 when IP Streaming is enabled 19 Diagram Connection Diagram Example using A CDN for release 2 0 when IP is enabled 20 Connecting the Camera to the Program of Choice 20 Skype Example...

Страница 3: ...rVIEW HD USB will also support H 264 video streaming It has a built in Ethernet network interface where both IP control and IP streaming can be initiated directly from the camera It will support eithe...

Страница 4: ...p Power Supply One 1 AC Cord Set for North America One 1 10 3 05m USB 2 0 Type A male to USB B male Cable Documentation International Version 999 6990 001 One 1 ClearVIEW HD USB PTZ Camera 998 6990 00...

Страница 5: ...at allows the user to choose the component HD output video resolution and format For the USB output use rotary switch settings 0 1 4 or 5 Please see the sections on available resolutions and concurren...

Страница 6: ...ate the top resolution that the PC and HD USB Camera can accomplish together and auto implement it and bob s your uncle 10 Settings Rotary Encoder The settings encoder is provided essentially for futu...

Страница 7: ...ions that can be both digital USB 2 0 or H 264 and Analog YPbPr These resolutions are the most used resolutions for HD video in both HD videoconferencing and broadcast For Analog YPbPr output all of t...

Страница 8: ...are support UVC drivers no additional software other than the application is required COMPATIBILITY The HD USB Camera will work with the following web browsers soft codecs computer operating systems a...

Страница 9: ...seconds at boot up then 2 Pick up the Vaddio IR Remote Commander and find the Data Screen button 3 Press and hold the Data Screen button on the remote for 4 seconds 4 The IP Address will appear on the...

Страница 10: ...Address and Subnet Mask numbers are displayed It is best to record the addresses that are in the computer so they can be re assigned when the operation is finished Enter 169 254 1 2 which is the defau...

Страница 11: ...s in this section For tighter shots it is recommended that the slower speed is used 4 Store Preset Button Clicking the Store button opens up a Store Preset pop up dialog box To set presets set up the...

Страница 12: ...e 12 of 32 Admin Pages Clicking on the Admin link button will open the Log in window Enter the default password password on this line and click on Log in After Login the Admin link buttons are exposed...

Страница 13: ...ny name room name room phone and help phone on a per camera basis The labels appear on every page at the top middle of the page Simply enter the room information and click Save By clicking on the Netw...

Страница 14: ...Save to keep the static IP information By clicking on the Security link button the Update Password screen is displayed The default user password is blank and the User password is password and the use...

Страница 15: ...button a set of self diagnostics will be displayed These diagnostics may help the Vaddio technical support team diagnose a problem with the HD USB camera The System link button is where the Firmware U...

Страница 16: ...ppropriate file and click on Begin Firmware Update When in doubt call Vaddio Tech Support for assistance After clicking on Begin Firmware Update a confirmation pop up and warning will be displayed Ple...

Страница 17: ...lease do not interrupt the firmware load Service Help information can be found under the Help tab Support phone numbers and e mail manuals FAQ s and System information is listed on this page Have this...

Страница 18: ...y soft codec application without taking up too much space This control page can be sized with the mouse moved around the screen and minimized to not block any part of the screen The Full button return...

Страница 19: ...aming is enabled The HD USB Camera has a Unicast streaming output suitable for up to six 6 concurrent users at lower resolutions This configuration shows four 4 concurrent users USB 2 0 Video using US...

Страница 20: ...with a quality USB 2 0 cable plug the USB B port of the camera to the USB A port of the computer A pop up window on the computer monitor will display the following a Found ClearVIEW HD USB b Found USB...

Страница 21: ...Analog only o 480i and 576i 4 3 LB and SQ USB Interface Connector Type B USB 2 0 Compliant Supported Drivers Standard UVC device no custom drivers Network Interface Connector RJ 45 10 100 Base T Supp...

Страница 22: ...roved by Vaddio can affect emission compliance and could void the user s authority to operate this equipment ICES 003 Compliance ICES 003 Issue 4 2004 This digital apparatus does not exceed the Class...

Страница 23: ...number e mail address shipping address product serial numbers and original purchase order number Describe the reason for repairs or returns as well as the date of purchase See the General RMA Terms an...

Страница 24: ...to Manual Direct 8x 01 04 08 00 FF 8x 01 04 08 02 FF 8x 01 04 08 03 FF 8x 01 04 08 2p FF 8x 01 04 08 3p FF 8x 01 04 38 02 FF 8x 01 04 38 03 FF 8x 01 04 38 10 FF 8x 01 04 48 0p 0q 0r 0s FF pqrs Focus p...

Страница 25: ...vices Improved Interoperability with Various UC software Clients Additional USB video resolution support has been added to the UVC endpoint to improve video quality for some UC soft clients that only...

Страница 26: ...can be found in the EasyUSB Tools Interoperability FAQ document Table HD USB Camera UC Client Interoperability Testing Software Client Operating System Issues Cisco Jabber Win 7 Mac OS X None Skype W...

Страница 27: ...ch type are Set Example COMMAND camera pan right RESPONSE OK Get Example COMMAND stream mode get RESPONSE streaming mode usb Syntax Error Example COMMAND camra pan right RESPONSE ERROR Additional prog...

Страница 28: ...PTIONS up Move the camera up down Move the camera down stop Stop the camera movement speed Optional integer from 1 20 that represents the speed Default 10 EXAMPLES camera tilt up Tilts the camera up a...

Страница 29: ...after a complete line is read Listed below are examples of history expansion Substitute the last command line N Substitute the Nth command line absolute as per history command N Substitute the comman...

Страница 30: ...address SYNOPSIS network settings get ping count count size size destination ip DESCRIPTION Method used to get the current network settings or check network OPTIONS settings Get the current network se...

Страница 31: ...t Get the current factory reset status on Enable factory reset on reboot off Disable factory reset on reboot EXAMPLES system factory reset get factory reset software off factory reset hardware Hardwar...

Страница 32: ...hone 763 971 4400 FAX 763 971 4464 www vaddio com 2012 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing are subject to ch...

Отзывы: