The pump capacitator
may be damaged.
It is recommended to call a pump
technician or licenced professional.
The pump shaft may
be locked or jammed.
Check for blockages that may be
causing the pump to seize:
1. Turn the power off.
2. Rotate the fan and ensure it spins
freely with no resistance.
3. Remove pump casing and check for objects
jammed between moving components.
It is recommended to call a pump
technician or licensed professional.
The electronic card in
the pressure controller
may be broken.
* Only applicable if
a pressure controller
has been installed.
If a pressure controller has been installed,
the electronic card in the controller may
need to be removed and replaced with
a new card, or a new unit entirely.
This should only be done by
a qualified electrician.
Voltage failure.
Check with a licensed electrical
contractor to ensure voltage
is correctly supplying the unit.
Refer electrical data in manual.
39
SYMPTOM
CAUSE
SOLUTION