The pump capacitator
may be damaged.
It is recommended to call a pump
technician or licenced professional.
The pump shaft may
be locked or jammed.
Check for blockages that may be
causing the pump to seize:
1. Turn the power off.
2. Rotate the fan and ensure it spins
freely with no resistance.
3. Remove pump casing and check for objects
jammed between moving components.
It is recommended to call a pump
technician or licensed professional.
The electronic card in
the pressure controller
may be broken.
* Only applicable if
a pressure controller
has been installed.
If a pressure controller has been installed,
the electronic card in the controller may
need to be removed and replaced with
a new card, or a new unit entirely.
This should only be done by
a qualified electrician.
Voltage failure.
Check with a licensed electrical
contractor to ensure voltage
is correctly supplying the unit.
Refer electrical data in manual.
The pump will not
start (no water is
being pumped and
it is not making
any noise).
There may be
no power supply
to the pump.
1. Ensure that the power is turned on and
check the connection to the power point.
2. Fuse may have blown.
3. Electrical power line may
have been damaged.
The pump motor
protection may
have tripped.
Ensure there is no mechanical
resistance on the pump rotor:
1. Disconnect all electrical power.
2. Remove the fan cover.
3. Rotate the fan by hand and
it should rotate freely.
Check that the pump is not blocked by external
objects that are causing the pump to seize.
1. Disassemble pipework and pump housing.
2. Clean impellers.
It is recommended to call a pump
technician or licensed professional.
Check that the power cables and relative
connections are not damaged.
Check if the pump winding is damaged
and replace if necessary.
This should only be done by
a qualified electrician.
Check the VFB-APC for pump
protection shutdowns.
The static head on
the discharge line
is greater than the
cut-in pressure.
Raise the cut-in pressure on the
VFB-APC to suit the application.
39
38
VADA FLOW BOSS
HORIZONTAL MULTISTAGE PUMP
VFB-HM80
INSTALLATION MANUAL
TROUBLESHOOTING
Having trouble? Sort it out here, quick smart.
If these solutions do not solve the problem, please visit your local Reece Irrigation & Pools branch.
SYMPTOM
CAUSE
SOLUTION
SYMPTOM
CAUSE
SOLUTION