VADA V-150VF Скачать руководство пользователя страница 7

13

12

VADA 

SUMP PUMP WITH VERTICAL FLOAT

 

V-150VF 

INSTALLATION MANUAL

1.   Turn the power on at the power point.

2.  Put a small amount of water in the  

tank/pit/well, enough to cover the pump 
completely. 

3.  The float switch will rise and the pump will 

start to empty the pit.

4.  As the pit empties, the float switch will fall 

and the pump will stop.

Note: 

There is a small port hole in the base of 

the pumping unit. On occasion, this will expel 
air bubbles should air become trapped within 
the pump housing. This is a normal operation.

Under normal conditions, the Vada V-150VF 
Sump Pump with Vertical Float requires low 
maintenance and is simple to service.

To avoid possible failures, we recommend 
periodically checking the flow and pressure 
supplied and current absorption for the 
following:

•  A decrease in pressure. This is a symptom 

of wear.

•  An increase in current absorption. This is  

a sign of abnormal mechanical friction in the 
pump and/or motor which may be caused 
by debris caught in the impeller.

CHECKING THE FLOW

1.  Get a bucket of a known size (e.g. 10 litre 

bucket) and place it near the Sump Pump. 

2.  Get a hose and connect it from the final 

discharge point to the bucket.

3.  When the pump is operating, time how long 

it takes to fill the bucket.

4.  Enter the bucket size and time it takes  

to fill the bucket to the formula below.

 1. 

Bucket size

 x 60 = V

 

 2.   V  ÷ 

time is takes to fill the bucket

 =  

flow in litres per minute

Example: 

I am using a 

10L

 bucket.  

It takes 

8.5 seconds

 for the bucket to fill. 

 1. 

10

 x 60 = 600

 

2.  600 ÷ 

8.5

 = 70

 

Therefore, my Sump Pump is producing  
70 litres per minute. 

 

If the answer (litres per minute) is between 
64 and 96, the sump pump is operating 
within the optimum operating range.

Note: 

Optimum operating range is  

4.3–3.2 metres head, 64–96 litres per minute.

OPERATION

SERVICE & MAINTENANCE

Do not run pump dry. Ensure 
that pump is submerged in water 
before operating.

Turn off power to motor and 
remove plug from power outlet 
before working on pump or motor.

ON

Содержание V-150VF

Страница 1: ...SUMP PUMP WITH VERTICAL FLOAT INSTALLATION MANUAL V 150VF...

Страница 2: ...invoice number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simpl...

Страница 3: ...ormance Discharge outlet connection 32mm BSP FI Suction inlet 10m Power cable Vertical float with automatic switch operation Cast iron pump housing Internal vortex impeller Built to handle clean and g...

Страница 4: ...Pumping liquid containing solids larger than maximum recommended particle size 15mm Pumping liquid containing abrasive solids stones ceramics etc PREPARING FOR INSTALLATION For a successful installat...

Страница 5: ...pework Ensure you have selected the position for your discharge outlet on the pit cut a hole to size on the pit and then secure a tank outlet or similar Note The length and the diameter of the dischar...

Страница 6: ...wer supply cord is supported by the delivery pipes at 3 metre intervals 2 Ensure the powerpoint is in a dry and flood free location 3 Plug the power supply cord into the 10 Amp powerpoint Do not switc...

Страница 7: ...of abnormal mechanical friction in the pump and or motor which may be caused by debris caught in the impeller CHECKING THE FLOW 1 Get a bucket of a known size e g 10 litre bucket and place it near the...

Страница 8: ...product lifespan Note Should you require further specific information or assistance with calculating the system duty of your application please contact your local Reece branch STORING THE PUMP PRODUC...

Страница 9: ...sibly looking to check that the float operation is not impaired Physically lift the float switch vertically if needed The float is caught on something and cannot rise Ensure that the float can move fr...

Страница 10: ...mp is being used with clean and grey water and is NOT being used with alternative fluids specifically abrasive corrosive or explosive fluids The pump is isolated from electrical supply during installa...

Страница 11: ......