SUMP PUMP WITH VERTICAL FLOAT

 

V-150VF 

INSTALLATION MANUAL

PART 1: PUMP LOCATION

Let’s get down to business. 

Note: 

Ensure the pump is being installed by a 

qualified, licensed personnel. The pump should 
be in good condition and should be used in a 
residential application.

1.  Ensure you have access to a 10A 

weatherproof outdoor powerpoint in a dry 
and flood free location. Do not plug the 
pump in.

2.  Position your sump pump in the  

tank/pit/well. If using a pit, we recommend 
using a minimum pit size of 300 (L) x 300 
(W) x 400 (H) to allow enough space for the 
float to rise.

Note: 

If needed, loop the nylon or steel  

rope through the top to lower the Sump Pump. 
Do not use the power cable or the float to 
lower the Sump Pump.

3.  Check the set up so far. The surface the 

pump sits on should be solid and there 
should be enough clearance between  
the base of the pit and suction inlet to 
prevent sediment and debris from entering 
the pump.

PART 2: DISCHARGE  

SET UP

Now that your sump pump is 
positioned, it’s time to set up the 
discharge pipework.

Ensure you have selected the position for your 
discharge outlet on the pit, cut a hole to size  
on the pit and then secure a tank outlet  
(or similar).

Note: 

The length and the diameter of the 

discharge hose impact the pressure and flow 
rate the sump pump can deliver. 

Note: 

All components used must have a 

pressure rating that exceeds the maximum 
pressure of the pump by an appropriate  
safety factor.

1.  Wrap a hex nipple in Teflon and fit it to the 

tank outlet (or similar).

2.  Fit a check valve to the hex nipple.  

The check valve will prevent fluid from  
re-circulating when the pump has stopped.

3.  Connect the discharge pipe to the outlet 

using one of the following options 

 

a.  If you are using a hard discharge pipe: 

 

  i.   Wrap a barrel union with Teflon tape.

 

  ii.   Fit the barrel union to the check valve 

to facilitate easy removal if needed.

In accordance with AS3350.2.41 
we are obliged to inform you that 
this pump is not to be used by 
children or infirm persons and 
must not be used as a toy.

The pump must be supplied by 
an outlet protected by a residual 
current device or earth leakage 
circuit breaker with a maximum 
rated residual current of 30mA.

Illustrations below are  
an example only.

400mm H

300mm L

300mm W

INSTALLATION

OFF

Содержание V-150VF

Страница 1: ...SUMP PUMP WITH VERTICAL FLOAT INSTALLATION MANUAL V 150VF...

Страница 2: ...invoice number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simpl...

Страница 3: ...ormance Discharge outlet connection 32mm BSP FI Suction inlet 10m Power cable Vertical float with automatic switch operation Cast iron pump housing Internal vortex impeller Built to handle clean and g...

Страница 4: ...Pumping liquid containing solids larger than maximum recommended particle size 15mm Pumping liquid containing abrasive solids stones ceramics etc PREPARING FOR INSTALLATION For a successful installat...

Страница 5: ...pework Ensure you have selected the position for your discharge outlet on the pit cut a hole to size on the pit and then secure a tank outlet or similar Note The length and the diameter of the dischar...

Страница 6: ...wer supply cord is supported by the delivery pipes at 3 metre intervals 2 Ensure the powerpoint is in a dry and flood free location 3 Plug the power supply cord into the 10 Amp powerpoint Do not switc...

Страница 7: ...of abnormal mechanical friction in the pump and or motor which may be caused by debris caught in the impeller CHECKING THE FLOW 1 Get a bucket of a known size e g 10 litre bucket and place it near the...

Страница 8: ...product lifespan Note Should you require further specific information or assistance with calculating the system duty of your application please contact your local Reece branch STORING THE PUMP PRODUC...

Страница 9: ...sibly looking to check that the float operation is not impaired Physically lift the float switch vertically if needed The float is caught on something and cannot rise Ensure that the float can move fr...

Страница 10: ...mp is being used with clean and grey water and is NOT being used with alternative fluids specifically abrasive corrosive or explosive fluids The pump is isolated from electrical supply during installa...

Страница 11: ......

Отзывы: