SUMP PUMP WITH VERTICAL FLOAT

 

V-150VF 

INSTALLATION MANUAL

KNOW YOUR PRODUCT

SPECIFICATIONS

Designed with a vertical float to suit the tightest installations and a vortex impeller for improved 
water flow and reduced clogging. This pump is constructed from cast iron for durability and is built 
to handle clean and greywater and soft solids up to 15mm O.D. at a 10% content or fine solids at 
1% concentration. The sump pump is supplied as standard with a 10m power cable length and 
connections to suit 32mm, 25mm and 20mm hose.

Note: 

A larger diameter hose or pipe will offer less resistance to flow and will give better performance.

Discharge outlet  
connection 32mm BSP FI

Suction inlet

10m Power cable

Vertical float with automatic 
switch operation

Cast iron pump housing

Internal vortex impeller

•  Built to handle clean and greywater with soft solids up to 15mm (no suspended solids like stones, 

pebbles, mulch or abrasive material such as sand, cement, dust or harsh detergents)

•  Optimum operating range: 4.3–3.2 metres head, 64–96 litres per minute

•  Max water temperature: 40°C

•  Max submersion depth: 6m

•  IP Rating: IP68

•  1PH, 230VAC ±10%, 50 Hz, (P1) 350W, (P2) 180W, Run current 1.75 A

PIT SIZE

The Vada Sump Pump with Vertical Float V150-VF is designed for small spaces. It requires a minimum 
pit size 300mm (L) x 300mm (W) x 400mm (H). 

If your pit is tapered, ensure the float can be fully engaged without getting caught on the pit wall.

HELPFUL HINT

400mm H

300mm L

300mm W

330mm

Содержание V-150VF

Страница 1: ...SUMP PUMP WITH VERTICAL FLOAT INSTALLATION MANUAL V 150VF...

Страница 2: ...invoice number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simpl...

Страница 3: ...ormance Discharge outlet connection 32mm BSP FI Suction inlet 10m Power cable Vertical float with automatic switch operation Cast iron pump housing Internal vortex impeller Built to handle clean and g...

Страница 4: ...Pumping liquid containing solids larger than maximum recommended particle size 15mm Pumping liquid containing abrasive solids stones ceramics etc PREPARING FOR INSTALLATION For a successful installat...

Страница 5: ...pework Ensure you have selected the position for your discharge outlet on the pit cut a hole to size on the pit and then secure a tank outlet or similar Note The length and the diameter of the dischar...

Страница 6: ...wer supply cord is supported by the delivery pipes at 3 metre intervals 2 Ensure the powerpoint is in a dry and flood free location 3 Plug the power supply cord into the 10 Amp powerpoint Do not switc...

Страница 7: ...of abnormal mechanical friction in the pump and or motor which may be caused by debris caught in the impeller CHECKING THE FLOW 1 Get a bucket of a known size e g 10 litre bucket and place it near the...

Страница 8: ...product lifespan Note Should you require further specific information or assistance with calculating the system duty of your application please contact your local Reece branch STORING THE PUMP PRODUC...

Страница 9: ...sibly looking to check that the float operation is not impaired Physically lift the float switch vertically if needed The float is caught on something and cannot rise Ensure that the float can move fr...

Страница 10: ...mp is being used with clean and grey water and is NOT being used with alternative fluids specifically abrasive corrosive or explosive fluids The pump is isolated from electrical supply during installa...

Страница 11: ......

Отзывы: