background image

31

30

VADA FLOW BOSS 

DIGITAL WATER SWITCHING UNIT

 

VFB-DSU 

INSTALLATION MANUAL

WARRANTY

You have purchased a quality product from 
Reece Australia. This product is covered  
by a 2 year product warranty, 2 year parts 
and labour. This warranty covers faults in the 
product construction, material, and assembly.

The first 12 months are covered by an onsite 
visit from service agent after assessed by 
Reece After Sales and deemed a possible 
product fault. Infield service may also be 
conducted digitally in circumstances where 
an agent cannot physically attend the site. 
Warranty is subject to an evaluation by the 
agent based on installation instructions set  
out in the product manual. 

A service fee may be charged to the customer 
if an aftersales service call is attended, and 
the fault is deemed to be a result of incorrect 
installation, or the points outlined below.  
Please note the site environment and associated  
product must be accessible and safe workplace 
for the service agent.

If a product is suspected of being faulty, please 
return to the Reece store it was purchased 
from and the product will be inspected 
by an authorised Reece representative. 
Products which are found upon inspection 
to be defective in construction, material, or 
assembly, will be repaired or exchanged with 
an equivalent product free of charge within 
the warranty period outlined above. Replaced 
items become Reece’s property. Charges may 
apply if installation terms have not been met. 
All replacement products will be available for 
collection without charge to the customer at 
the nearest Reece branch to the customer’s 
location, or elsewhere as agreed between the 
customer and Reece. Please note, warranty 
repairs may only be performed by our service 
representatives or an authorised customer 
service workshop, and any attempt to repair 
the device by the customer or unauthorised 
third parties shall terminate the warranty.

WARRANTY CONDITIONS

The warranty will apply only under all the 
following conditions: 

•  The pump has been installed by a qualified, 

licensed personnel. 

•  The pump is returned in good condition  

and has not arrived damaged. 

•  The pump is located so that it will NOT  

be prone to freezing. 

•  The pump is being used with clean water 

only and is NOT being used with alternative 
fluids specifically abrasive, corrosive, or 
explosive fluids.  

•  The pump is isolated from electrical supply 

during installation and any subsequent 
service work. 

•  The electrical installation is in accordance 

with the national wiring rules (AS/NZS 3000).

•  The pump has NOT been lifted/moved/ 

carried by the electrical or float switch cables. 

•  The steps outlined in this manual and all 

accompanying quick start guides have been 
adhered to.

•  The pump has been installed for and 

subjected to domestic residential use only 
subject to local building a municipality 
guideline. 

•  Failure is due to a fault in the manufacture  

of the project. In this case, proof of 
purchase, date of purchase and serial 
number is required. 

This warranty does not include faults caused by:

•  Failure to adhere to the conditions above. 

•  Normal wear and tear. 

•  Inadequate or complete lack of maintenance. 

•  Chemical, electrochemical, or electrical 

influences. 

•  Harsh detergents or abrasive cleaners used 

on product finishes. 

•  Unsuitable or improper use.

•  Incorrect installation or installation not in 

accordance with the instructions provided.

•  Inadequate protection of the pump.

EXCLUSIONS

To the fullest extent permitted by law, Reece 
excludes all liability for damage or injury to 
any person, damage to any property and any 
indirect consequential or other loss or damage. 
To the maximum extent permitted by law, 
Reece excludes all warranties other than those 
set out above.

Содержание FLOW BOSS VFB-DSU

Страница 1: ...DIGITAL WATER SWITCHING UNIT INSTALLATION MANUAL VFB DSU ...

Страница 2: ...ce number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simple installation and high quality you can hold your head high knowing your reputation is protected It s Vada Performance simplified THANK YOU Scan for set up support ...

Страница 3: ...PA 1 bar Max operating pressure 1000kPA 10 bar Minimum flow rate 1 lpm Voltage 1 230 240V 50Hz Maximum electrical load 10A 2400W IP Rating IP44 Vada strongly recommends installing the float switch supplied in the tank on site Installing a float switch prevents air from re entering the suction line and damaging your Vada product Installing a float switch also reduces build up from tank debris enter...

Страница 4: ...ion pipe internal diameter must be no smaller than 25mm x2 mesh inline filters Discharge pipe internal diameter must be no smaller than 25mm 16mm hole saw Thread tape Access to a 10A outdoor power point Inline filter AKA Y Strainer Isolation valve Swing check valve Float switch tank If the incoming mains pressure to your property is greater than the specified 1000 kPa 10 bar you MUST fit a pressur...

Страница 5: ... type of device to the entire house will extend the life of other appliances such as washing machines hot water service and dishwashers This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person respons...

Страница 6: ...pple from the union Rethread the nipple into the switching unit making sure the union nut remains on the nipple Re join the union to complete connection 6 Connect the VFB DSU to the discharge port on the pump 7 Connect the incoming mains water supply to the MAINS port on the VFB DSU This is marked MAINS with an arrow pointing out of the VFB DSU indicating water flow direction Note Brace this fitti...

Страница 7: ...pply by either a Hard wiring Local authorities may require the pump to be hard wired Important If this applies to you the electrical connection must be done by a qualified electrician with pump knowledge according to the National wiring rule AS NZS 3000 and or any local council requirements WARNING Hazardous voltage can cause shock burn or cause death The supply voltage for the Digital Water Switc...

Страница 8: ...e This indicates to the switching unit that there is no water in the tank and to switch to mains supply operation 4 Open an outlet on the household side of the VFB DSU The VFB DSU should now be allowing mains water to supply the demand 5 Close the tap and replace the float switch connection If there are any variations to these outcomes please refer to the Troubleshooting section on page 28 70mm ab...

Страница 9: ...nstallation will be random 4 To set the date and time press the Time Set button 5 Press either up or down arrow to select the correct day of the month When the correct value is observed press the Time Set button again 9 In the event the user inputs incorrect information the Invalid Data screen will appear 10 The VFB DSU has been set to its basic settings For advanced settings and additional functi...

Страница 10: ... which the pump will stop aka cut out 1 Press the RESET button again to select the Cut Out Flow 2 Press the up or down arrow to select the appropriate cut out level Note It is recommended the Cut Out flow rate be 1 lpm Minimum Pressure 1 Press the RESET button until you reach Min Pressure 2 Press the up or down arrow to select the appropriate pressure Note The Min Max pressure required for the swi...

Страница 11: ...50Hz Max electrical load 10A 2400W Power standby 3 5W Control power on 30W IP rating IP44 Min flow rate 1lpm Min mains pressure 1 bar Max operating pressure 10 bar Min max water temperature 1 C 40 C Min max ambient temperature 1 C 40 C CONNECTION Mains water supply inlet 25mm FI BSP Pump connection 25mm FI BSP Water outlet connection 25mm FI BSP TECHNICAL INFORMATION C F H I A B J G D E A 52mm B 1...

Страница 12: ...ystem will automatically default to mains water supply When power is restored the switching unit will revert to normal operation Loss of Mains Supply Water If town supply water is shut off in your area the switching unit may not be able to detect water demand in the household e g if the toilet cistern needs refilling You can override normal control and start the pump to supply water out of the rai...

Страница 13: ...lly connected Ensure that it is isolated from electrical supply during installation and any subsequent service work Unit should only be serviced by qualified personnel or licensed service agent OFF 6 If rainwater is detected the system will revert to normal operation 7 If no rainwater is detected then the switching unit will go to a further 7 day lock out as per step 4 The unit will continue to au...

Страница 14: ...k maximum run time setting OVER CURRENT Error Code 3 Over current detected measured current exceeds 10amps 1 Check pump for mechanical resistance Refer to troubleshooting in pump manual 2 Check pump motor for electrical faults Refer to troubleshooting in pump manual NO PUMP CONNECTED CHECK FUSE Error Code 4 No load detected 1 Check to make sure the pump is connected 2 Check for blown fuse on the b...

Страница 15: ...ater 3 Remove pump barrel union 4 Inspect clean replace filter Pump is not primed 1 Open gate valve and prime the pump Refer to pump manual on how to prime the pump 2 Reset the switching unit by pressing Reset key SYMPTOM CAUSE SOLUTION Pump continually runs or cycles on and off consistently over time when no outlets open Leak in the plumbing system 1 Identify where the leak is e g toilet or tap l...

Страница 16: ...atives or an authorised customer service workshop and any attempt to repair the device by the customer or unauthorised third parties shall terminate the warranty WARRANTY CONDITIONS The warranty will apply only under all the following conditions The pump has been installed by a qualified licensed personnel The pump is returned in good condition and has not arrived damaged The pump is located so th...

Страница 17: ......

Отзывы: