It is recommended to connect the vacuum set only with parts and products supplied by VacuumChambers.eu. 
If the customer connects the vacuum set or its parts with elements or devices from other manufacturers, the 
customer is solely responsible for the appropriate selection of these elements, their compatibility and quality 
of  their  connection.  The  manufacturer  is  not  responsible  for  any  damage  or  losses  caused  by  incorrect 

selection, matching, use or combination of the products. The above principles apply in particular to vacuum pumps purchased 
from other suppliers. 

 

Depending  on  the  selected  model  or  on  the  customer's  individual  order,  the  vacuum  set  can  be  equipped  with:  fitting 

muffler, stirrer mechanism, vacuum trap or vacuum feedthrough with pouring hose and mechanical flow controller. 

A.

 

Fitting muffler.

 

 

Photo 9: Fitting muffler and air manifold with mounted muffler.

 

The fitting muffler (Photo 9) disperses the airflow getting into the chamber while balancing the vacuum. It prevents casting 

materials from spilling inside the chamber. This accessory should be screwed manually (not using any tools) onto the mounted 
air manifold on the internal side of the tank or on the bottom side of the lid. The diffuser is not included as a standard accessory 
to all the vacuum sets. 

B.

 

Vacuum feedthrough with pouring hose and mechanical flow controller. 

The  feedthrough  integrated  with  the  vacuum  chamber  (Photo  10)  enables  to  supplying  of  flooding  materials  from  the 

external container directly into the interior of the chamber under vacuum. The mechanical flow controller (4) included in the set 
allows to precise process control. To regulate the process of collecting material into the chamber, operate the wingnut located 
on the regulator. It allows to reduce or block pouring hose capacity. 

When using the vacuum set, the pouring hose becomes dirty with the supplied materials. This situation is a natural wear 

and tear and is not subject to warranty. The customer is obliged to always replace a dirty hose in accordance with instructions 
below. 

To  remove  the  hose  from  the  vacuum  feedthrough  (1),  loosen  the  nut  (2)  with  a  spanner.  The  hose  should  be  at  ease 

removed from the feedthrough. The next step is to remove the flow regulator (4) from the hose after loosening the wing head 
screw. 

Put the mechanical flow regulator (Photo 11) on the new hose. The hose should be centrally located under the regulator 

stamp, between the stamp and the opposite wall. Tighten the regulator with the wing head screw as needed. 

 
 

 

 

 

Photo 10: Vacuum feedthrough with pouring hose and flow controller mounted on the tank.

 

 

Photo 11: Mechanical flow controller. 

The spare end  of  the hose should  be  placed  in  the vacuum feedthrough (Photo 10). Sufficiently long section of the hose 

should be inside the tank. Use one spanner to tighten the feedthrough nut and other spanner to hold the feedthrough.  

C.

 

Stirrer mechanism. 

The stirrer mechanism is an additional accessory of the vacuum chamber. It facilitates and speeds up the degassing process. 

The stirrer mechanism can only be installed in the chamber provided for this purpose. Photo 12 shows the chamber lid (1) with 
the agitator (4) attached to it. 

 

Photo 12: Agitator mounted on the lid. 

stamp 

Содержание VC0918SS

Страница 1: ...ol Do not dispose of that product as unsorted municipal waste Used equipment should be sent to an electro waste collection point Nature friendly company All photos used in this manual are illustrative...

Страница 2: ...s an example of a vacuum chamber The vacuum chamber body is made of aluminium powder coated steel or stainless steel depending on its type The lid of the chamber is made of thick polycarbonate or temp...

Страница 3: ...ly fill the vacuum pump Photo 7 with the oil provided with the set To do that place the pump on the flat horizontal surface unscrew the red plug 1 and pour the oil through the oil feed hole For some m...

Страница 4: ...ior of the chamber under vacuum The mechanical flow controller 4 included in the set allows to precise process control To regulate the process of collecting material into the chamber operate the wingn...

Страница 5: ...inches 10 If it is difficult or impossible to close at least one clamp make sure that the lid is correctly positioned If necessary the length of the clamps can be adjusted In order to avoid damage of...

Страница 6: ...nge 5 Outer tank 6 Vacuum chamber connecting valve 3 4 5 6 outer tank 12 from the inner tank as their accumulation may result in dangerous pressure build up in the inner tank Therefore the inner tank...

Страница 7: ...the ON position valve handle parallel to the valve 5 Turn on the vacuum pump 6 In the first phase of the suction it may be necessary to press the lid to the tank until the increasing vacuum in the cha...

Страница 8: ...e operated by trained technicians mentally and physically able to operate the vacuum set and its individual components Do not use the device or any of its parts for purposes other than those for which...

Страница 9: ...17...