SPECIAL SITUATIONS - NEW & EXISTING HOMES (CONTINUED)

Step 5

Center VacPan under
cabinet so as to
avoid standards and
cabinet supports.  Use
a 1x4 and a 2x4 under pipe to
get correct height.  Dry fit horizontal pipe
into sweep 90 that comes up under cabinet.  We recom-
mend having cabinet people put a false bottom in this cabinet.  Pipe
opening is 

not

centered to opening in mopboard.  Measure 4" to right side of cen-

ter and 2-1/2" to left of center, 6-1/2" width x 1-3/4" height over all.  If installation of
VacPan is only possible from front of mopboard, cut opening 6-1/2" x 3-1/2" and use
oversized trim plate.

PAGE 9

How to Install the System (Continued)

Содержание 760 Dual Motor

Страница 1: ...hillips Electrical Tape or Duct Tape Tie Wraps Wire Coat Hanger Hammer and Nail Puller Side Cutters Wire Connectors for 18 1 00 mm wire Flashlight Drywall Saw Wire Stripper Crimping Tool Installing a...

Страница 2: ...areas of the house can be cleaned from selected inlet valve loca tions If an electrical beater brush is to be used now or in the future the inlet valve should be located within five feet of an electri...

Страница 3: ...line will greatly depend on the construction of the house and location of the power unit Multi Story Houses While roughing in tube lines during construction is comparatively simple existing two and th...

Страница 4: ...ahead and create a rough bead on the inside of the fitting This bead will reduce airflow and could cause a clog The tubing should be inserted all the way into the fitting and twisted a quarter turn t...

Страница 5: ...installed and grounded in accor dance with all local codes and ordinances WARNING Electric shock is a risk when the equipment grounding conductor is improperly connected Check with a quali fied electr...

Страница 6: ...nt tabs facing adapter elbow Line up slots on the mounting plate with tabs on adapter elbow then rotate mounting plate into an upright position Be sure approximately 6 150 mm of 18 2 1 00 mm solid wir...

Страница 7: ...re with screws Drill a 2 1 4 2 9 16 hole below the 90 adapter and connect PVC to trunk line SPECIAL SITUATIONS EXISTING HOMES Step 3 Floor Installation of Inlet Valve While the normal installation of...

Страница 8: ...ions of these instructions Happy vacuuming Helpful Hint Take measurement from floor to bottom of electrical box Add 1 7 8 to get Center Point of Vac Mounting Plate PAGE 8 How to Install the System Con...

Страница 9: ...90 that comes up under cabinet We recom mend having cabinet people put a false bottom in this cabinet Pipe opening is not centered to opening in mopboard Measure 4 to right side of cen ter and 2 1 2 t...

Страница 10: ...provide a pocket for dirt to drop into Always run a branch line out of the side or top of the trunk line No 18 2 1 00 mm low voltage wire follows tubing from each inlet valve Junctions or splices usi...