Active Front End (AFE)
vacon • 41
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
4
NOTE!
All fuses are flush-end type. If some other type is needed, contact your distributor.
NOTE!
Fuses for FI9 is fuse links type and for FI10 and FI13 are flush-end type. If some other type is needed,
contact your distributor.
Table 17. Bussman DC fuse selection, mains voltage 465–800 Vdc
Module
DC fuses
Type
Code
Enclosure
size
Bussman
type [aR]*
U
N
[V]
I
N
[A]
Size
Q'ty
AFE
NXA_0168 5
FI9
170M6458
690
500
3BKN/50
2
NXA_0205 5
FI9
170M6458
690
500
3BKN/50
2
NXA_0261 5
FI9
170M6462
690
800
3BKN/50
2
NXA_0385 5
FI10
170M6466
690
1250
3BKN/50
2
NXA_0460 5
FI10
170M6466
690
1250
3BKN/50
2
NXA_1150 5
FI13
170M7084
690
3000
4BKN/65
2
NXA_1300 5
FI13
170M7084
690
3000
4BKN/65
2
Table 18. Bussman DC fuse selection, mains voltage 465–800 Vdc, North-America
Module
DC fuses
Type
Code
Enclosure
size
Bussman
type [aR]*
U
N
[V]
I
N
[A]
Size
Q'ty
AFE
NXA_0168 5
FI9
170M1777
800
400
FU/70
2
NXA_0205 5
FI9
170M1777
800
400
FU/70
2
NXA_0261 5
FI9
170M1781
800
630
FU/70
2
NXA_0385 5
FI10
170M6499
1200
1100
3BKN/90
2
NXA_0460 5
FI10
170M6499
1200
1100
3BKN/90
2
NXA_1150 5
FI13
170M6499
1200
1100
3BKN/90
3x2
NXA_1300 5
FI13
170M6499
1200
1100
3BKN/90
3x2
Содержание NX series