Page 2 (10)
Vacon
Vacon Plc
Phone: +358-(0)201 2121
Fax:
+358-(0)201 212 205
Service: +358-(0)40-8371 150
E-mail: [email protected]
7-segment Control panel
RST
PG
UD008K17
MON PAR REF BTNS
RUN READY FAULT
=
Reset button:
Resets faults
=
Page button:
Changes active menu page
=
Start button:
Starts the motor if the panel is the
active control source
=
Stop button:
Stops the motor if the panel is the
active control source
1.
GENERAL
The 7-segment control panel of the Vacon
frequency converter has a six-digit LED display,
three drive status indicators, four active menu
page indicators and eight push-buttons.
The panel is removable and it has full galvanic
isolation from the mains potential. The same
panel can be used with all Vacon frequency
converters.
In other questions and problems with Vacon
CX/CXL/CXS frequency converter, please refer
to the CX/CXLCXS User's Manual or the Five
In One+ Application Manual
DRIVE STATUS INDICATORS
RUN =
lights when the motor is
running
READY =
lights when mains voltage has
been applied and the drive is
ready to operate
FAULT =
lights if fault occurs
DISPLAY
Displays parameter values,
monitoring data, etc., six digits
ACTIVE MENU PAGE INDICATORS
BTNS
=
Programmable push-button
(menu page)
REF
=
Reference values (menu
page)
PAR
=
Parameters (menu page)
MON
=
Monitoring values (menu page)
(none)
=
Fault history (menu page)
PUSH-BUTTONS
=
Tab button:
Toggles between display item indication
and item data
=
Arrow up/down buttons:
Changes item or data value
=
Enter button:
Confirms the parameter value setting.
Acts as push-button on the
programmable push-button page.
On the PAR-page the parameter
number on the display will be changed
into a higher parameter group.
Figure 1. Control panel with LED display.