background image

sales companies and representative offices:

finland

Helsinki
Vacon Plc
Äyritie 8
01510 Vantaa
telephone: +358 (0)201 212 600
fax: +358 (0)201 212 699

Tampere
Vacon Plc
Vehnämyllynkatu 18
33580 Tampere
telephone: +358 (0)201 2121
fax: +358 (0)201 212 750

australia

Vacon Pacific Pty Ltd
5/66-74, Micro Circuit
Dandenong South, VIC 3175
telephone: +61 (0)3 9238 9300
fax: +61 (0)3 92389310

austria

Vacon AT Antriebssysteme GmbH
Aumühlweg 21
2544 Leobersdorf
telephone: +43 2256 651 66
fax: +43 2256 651 66 66

belgium

Vacon Benelux NV/SA
Interleuvenlaan 62
3001 Heverlee (Leuven)
telephone: +32 (0)16 394 825
fax: +32 (0)16 394 827

brazil

Vacon Brazil
Alameda Mamoré, 535
Alphaville - Barueri -SP
Tel. +55 11 4166-5707
Fax. +55 11 4166-5567

canada

Vacon Canada
221 Griffith Road
Stratford, Ontario N5A 6T3
telephone: +1 (519) 508-2323
fax: +1 (519) 508-2324

china

Vacon Suzhou Drives Co. Ltd.
Beijing Branch
A528, Grand Pacific Garden Mansion
8A Guanghua Road
Beijing 100026
telephone: + 86 10 51280006
fax: +86 10 65813733

czech republic

Vacon s.r.o.
Kodanska 1441/46
110 00 Prague 10
telephone: +420 234 063 250
fax: +420 234 063 251

france

Vacon France
ZAC du Fresne
1 Rue Jacquard - BP72
91280 Saint Pierre du Perray CDIS
telephone: +33 (0)1 69 89 60 30
fax: +33 (0)1 69 89 60 40

germany

Vacon GmbH
Gladbecker Strasse 425
45329 Essen
telephone: +49 (0)201 806 700
fax: +49 (0)201 806 7099

Vacon OEM Business Center GmbH
Industriestr. 13
51709 - Marienheide
Germany
Tel. +49 02264 17-17
Fax. +49 02264 17-126

india

Vacon Drives & Control Plc
Plot No 352
Kapaleeshwar Nagar
East Coast Road
Neelangarai
Chennai-600041
Tel. +91 44 244 900 24/25

italy

Vacon S.p.A.
Via F.lli Guerra, 35
42100 Reggio Emilia
telephone: +39 0522 276811
fax: +39 0522 276890

the netherlands

Vacon Benelux BV
Weide 40
4206 CJ Gorinchem
telephone: +31 (0)183 642 970
fax: +31 (0)183 642 971

norway

Vacon AS

Bentsrudveien 17

3080 Holmestrand
telephone: +47 330 96120
fax: +47 330 96130

romania

Vacon Romania - Reprezentanta
Cuza Voda 1
400107 Cluj Napoca
Tel. +40 364 118 981
Fax. +40 364 118 981

russia

ZAO Vacon Drives
Ul. Letchika Babushkina 1,
Stroenie 3
129344 Moscow
telephone: +7 (495) 363 19 85
fax: +7 (495) 363 19 86

ZAO Vacon Drives
2ya Sovetskaya 7, office 210A
191036 St. Petersburg
telephone: +7 (812) 332 1114
fax: +7 (812) 279 9053

slovakia

Vacon s.r.o. (Branch)
Seberiniho 1
821 03 Bratislava
Tel. +421 243 330 202
Fax. +421 243 634 389

spain

Vacon Drives Ibérica S.A.
Miquel Servet, 2. P.I. Bufalvent
08243 Manresa
telephone: +34 93 877 45 06
fax: +34 93 877 00 09

sweden

Vacon AB
Anderstorpsvägen 16
171 54 Solna
telephone: +46 (0)8 293 055
fax: +46 (0)8 290 755

thailand

Vacon South East Asia
335/32 5th-6th floor
Srinakarin Road, Prawet
Bangkok 10250
Tel. +66 (0)2366 0768

ukraine

Vacon Drives Ukraine (Branch)
42-44 Shovkovychna Str.
Regus City Horizon Tower
Kiev 01601, Ukraine
Tel. +380 44 459 0579
Fax +380 44 490 1200

united arab emirates

Vacon Middle East and Africa
Block A, Office 4A 226
P.O.Box 54763
Dubai Airport Free Zone
Dubai
Tel. +971 (0)4 204 5200
Fax: +971 (0)4 204 5203

united kingdom

Vacon Drives (UK) Ltd.
18, Maizefield
Hinckley Fields Industrial Estate
Hinckley
LE10 1YF Leicestershire
telephone: +44 (0)1455 611 515
fax: +44 (0)1455 611 517

united states

Vacon, Inc.
3181, Black Gap Road
Chambersburg, PA 17202
telephone: +1 (877) 822-6606
fax: +1 (717) 267-0140

head office and
production:

Vaasa
Vacon Plc
Runsorintie 7
65380 Vaasa
[email protected]
telephone: +358 (0)201 2121
fax: +358 (0)201 212 205

production:

Suzhou, China
Vacon Suzhou Drives Co. Ltd.
Building 11A
428# Xinglong Street, SIP
Suchun Industrial Square
Suzhou 215126
telephone: + 86 512 62836630
fax: + 86 512 62836618

Naturno, Italy
Vacon S.R.I
Via Zone Industriale, 11
39025 Naturno

production:

Chambersburg, USA

3181 Black Gap Road
Chambersburg, PA 17202

TB Wood's (India) Pvt. Ltd.
#27, 'E' Electronics City
Hosur Road
Bangalore - 560 100
India
Tel. +91-80-30280123
Fax. +91-80-30280124

Содержание 10

Страница 1: ......

Страница 2: ...s con nected to mains even if the motor is not running The control I O terminals are isolated from the mains poten tial However the relay output terminals may have a danger ous control voltage present...

Страница 3: ...crew or DIN rail mounting Figure 1 Screw mounting left and DIN rail mounting right NOTE See the mounting dimensions on the back of the drive Leave free space for cooling above 100 mm and below 50 mm V...

Страница 4: ...bles is 0 5 0 6 Nm Figure 3 Vacon 10 power connections MI1 Figure 4 Vacon 10 power connections MI2 MI3 1 230V 3 400V Motor out MAINS MOTOR Strip the plastic cable coating for 360 earthing L1 L2 N L3 U...

Страница 5: ...pport 358 0 40 837 1150 Email vacon vacon com 2 2 2 2 Control cabling Figure 5 Open the cover Figure 6 Install the control cables See next page Strip the plastic cable coating for 360 earthing Control...

Страница 6: ...Vacon 10 RS 485 I O terminals Terminal Signal Factory preset Description 3 GND I O signal ground 6 24Vout 24V output for DI max load 50 mA 7 GND I O signal ground 8 DI1 Digital input 1 1 Start forward...

Страница 7: ...indicate the status of the drive provide the user with information on faults and help the user to select the control place or fieldbus address Figure 1 The status LEDs of Vacon 10 RS 485 The followin...

Страница 8: ...switch is in STOP posi tion 5 Connect the drive to mains 6 This step is not valid for API RS 485 7 Perform test run without motor see the User Manual at www vacon com 8 Run no load tests without motor...

Страница 9: ...When keypad is selected as the control place Vacon RS 485 starts forward when the START button is pressed The frequency reference can be increased for 5Hz with each press of the button Green Green Red...

Страница 10: ...ddress selection The slave addresses are binary coded and indicated with blinking LEDs Press the STOP button to move to the next address 4 Address 1 Address 2 Address 3 Address 4 Address 5 Address 6 A...

Страница 11: ...of the motor M1 6 Motor power 5 Calculated actual nominal power of the motor M1 7 Motor voltage V 6 Motor voltage M1 8 DC link voltage V 7 Measured DC link voltage M1 9 Unit temperature C 8 Heat sink...

Страница 12: ...nit 107 P1 15 Torque boost 0 1 0 109 0 Not used 1 Used P2 1 Control place 1 3 3 125 1 I O terminal 2 Keypad 3 Fieldbus P2 2 Start function 0 1 0 505 0 Ramp 1 Flying start P2 3 Stop function 0 1 0 506...

Страница 13: ...r of error messages yyy 0 999 Number of good messages S2 2 Fieldbus protocol 0 1 1 809 0 FB disabled 1 Modbus S2 3 Slave address 1 255 810 S2 4 Baud rate 0 5 5 811 0 300 1 600 2 1200 3 2400 4 4800 5 9...

Страница 14: ...rt pulse long pulse Red LED blinking sequence Fault code Fault name 1 Overcurrent 2 Overvoltage 3 Earth fault 8 System fault 9 Undervoltage 13 Frequency converter undertempera ture 14 Frequency conver...

Страница 15: ...torage temperature 40 C 70 C Enclosure class IP20 Relative humidity 0 95 RH non condensing non corrosive no dripping water Altitude 100 load capacity no derating up to 1000m 1 derating for each 100m a...

Страница 16: ...0 contin current IN A 150 overload current A P kW A Vacon 10 1L 0001 2 1 7 2 6 0 25 4 2 MI1 Vacon 10 1L 0002 2 2 4 3 6 0 37 5 7 MI1 Vacon 10 1L 0003 2 2 8 4 2 0 55 6 6 MI1 Vacon 10 1L 0004 2 3 7 5 6 0...

Страница 17: ......

Страница 18: ...Bentsrudveien 17 3080 Holmestrand telephone 47 330 96120 fax 47 330 96130 romania Vacon Romania Reprezentanta Cuza Voda 1 400107 Cluj Napoca Tel 40 364 118 981 Fax 40 364 118 981 russia ZAO Vacon Driv...

Отзывы: