Ceiling Mouting
The heating panel must be at least 30 cm away from all objects, walls, and other obstacles.
The minimum distance from the ceiling is 4 cm to allow an airflow which will prevent the
heating panel from overheating. The minimum distance from the bottom of the heating
panel to the floor is 185 cm. Choose a sturdy, even ceiling made of heatproof material to
hang the heating panel.
Accessories:
1. Plastic rail
4 pcs
2. Metal screw
4 pcs
3. O-rings
4 pcs
4. H-type metal bracket
1pcs
Mounting steps:
1.
Use the H-bracket to mark the holes in the ceiling. Position the H-bracket such that, when
the heating panel is installed, the minimum distances are guaranteed. Ensure that the
hanging frame is installed with the correct side on top (see Figure 1). Check that there are
no cables in the ceiling before drilling at the marked points.
2.
Drill holes with the drill bit (see Figure 2).
3.
Push the plugs into the holes (see Figure 3).