background image

Safety Precautions

For your safety, follow these precautions when using your 

VacMaster

®

 VP325:

 

  Read Operator’s Guide carefully before using the machine for 

  the 

fi

 rst time.

 

  Do not use the VP325 on wet or hot surfaces, or near a heat source.

 

  Do not immerse machine or power cord in water or any other liquid.

 

  Plug VP325 into grounded power sources only.  

    Do not use extension cord.
 

  To disconnect, unplug directly from power source.  Do not disconnect   

  by pulling cord.
 

  Do not operate machine with damaged power cord.

 

  Only use VacMaster

®

 vacuum pouches and accessories.

 

  Do not allow to be used as a toy.  Close supervision is necessary  

 

    when used by or near children.
 

  Only use VP325 for its intended use.

Gas Flush System

Products which would be damaged by high pressure must be subjected to a lower 
vacuum or the pressure must be counterbalanced by in

fl

 ating the bag with inert gas.

The gas 

fl

 ush system is designed to remove the oxygen and replace it with a mixture 

of Carbon Dioxide and Nitrogen to extend shelf life and provide a higher quality 
product to the consumer. This is bene

fi

 cial when packaging items that shouldn’t be 

compressed. This includes but is not limited to soft fruits, dried foods, chips, pasta, 
and pre-cooked meals. By adding a mixture of Carbon Dioxide and Nitrogen, the food 
will stay fresh longer while keeping its original shape.

How To Use:

Consult your local authorized gas supplier for assistance in buying, regulating, and 
connecting the gas to the machine.

Gas Fill Operating Instructions:

Connect the required gas cylinder, (complete with regulator), to the machine by hose. 
The Regulator may never be set more than atmospheric pressure, approximately 14 
psi. The appropriate level should be between 5 and 12 psi. 

To add gas 

fl

 ush to the normal operating cycle, follow the operating instructions. If 

there is no gas 

fl

 ush time set, there will be no gas 

fl

 ush in the process of sealing. 

To use the gas 

fl

 ush add increments of .1 seconds to the timer. It may take several 

adjustments to get the package to the desired 

fi

 ll level.

Содержание VP325

Страница 1: ...Operator s Guide VP325 Chamber Machine Commercial Vacuum Packaging System...

Страница 2: ...mess The VP325 Chamber Machine uses commercial technology Simply place the pouch to be sealed inside the chamber and close the lid This activates the vacuum pump and the vacuum and sealing process be...

Страница 3: ...osed plastic oil bottle 2 With a phillips screwdriver remove the 4 screws to open the back of the cabinet 3 Locate the oil fill cap on the top of the vacuum pump 4 With pliers or vice grips turn cap c...

Страница 4: ...gs Several sizes available to meet your packaging needs Terrific for hundreds of applications in and out of the kitchen Safe for freezer refrigeration and microwave use Cook in bags can be boiled Bag...

Страница 5: ...only fresh foods Do not package old or rancid foods An already bad product does not improve with vacuum packaging Fresh foods Meats vegetables cheeses etc should be refrigerated at 34 F or below or f...

Страница 6: ...oxygen and replace it with a mixture of Carbon Dioxide and Nitrogen to extend shelf life and provide a higher quality product to the consumer This is beneficial when packaging items that shouldn t be...

Страница 7: ...cycle Used to keep lid closed when machine is not in use or while machine is in storage Filler Plates used to take up space in the vacuum chamber Using the plates will result in a faster vacuum time s...

Страница 8: ...25 seconds Adjust vacuum accordingly to achieve the vacuum required Gas Flush Press the SET button until the GAS FLUSH indicator lights Adjust the gas flush time by using the or buttons For an initial...

Страница 9: ...h seal Note A positive seal will look clear upon inspection If the seal is spotty or incomplete increase the sealing time by 0 2 seconds If the seal is white or milky decrease seal time by 0 2 seconds...

Страница 10: ...ing drain bolt 7 Capture oil from pump When oil is completely drained replace and tighten bolt Dispose of old oil properly according to your local and state regulations 8 Follow the Adding Oil to Vacu...

Страница 11: ...nspect the brown Teflon tape covering the seal wire If the tape becomes burnt or torn replace Lid gasket make sure gasket and the top of the chamber remains clean and free of debris Troubleshooting No...

Страница 12: ...Lid 2 2 Chamber Lid 1 979301 3 Lid Gasket 1 979202 4 Teflon Tape 2 979822 5 Top Bar 2 979305 6 Seal Pad 2 976598 7 Seal Wire 2 979109 8 Clamp 4 9 Seal Bar 2 10 Brass Contacts 4 11 Seal Bar Tension Blo...

Страница 13: ...Board 1 979127 4 Cable Sheath 1 5 Straight Way Connector 1 6 Cover Plate 1 7 Inlet Ring 1 8 Inner Inlet Ring 1 9 Exhaust Tube 1 10 Rear Cover 1 11 Buckle on Cover 1 12 Power Switch Bracket 1 979137 13...

Страница 14: ...l 1 11 Circuit Board Port 1 12 Frame for Wire Holder 1 13 Solenoid Combined Valve 1 979560 14 Wiring Port 1 15 Vacuum Pump 1 979320 16 Silicone Rubber Tube 1 17 Proximity Switch Seat 1 979354 18 Proxi...

Страница 15: ...Notes...

Страница 16: ...and workmanship refund of the purchase price or grant of a reasonable allowance on account of such defects all as set forth above ARY Inc is not responsible for any consequential damages resulting fr...

Отзывы: