9
ARY, Inc. | 5200 W 110th Street Suite 200, Overland Park, KS 66211 | www.VacMasterFresh.com | 800-821-7849
VP321 Chamber Vacuum Sealer |
User Guide
How to Use
Set Up - Powering up the VP321
1.
Attach the power cord and plug the machine into a grounded
electrical outlet - Properly insert the electrical cord into the
power outlet on the back of the machine and then plug the
cord into the wall outlet.
2.
Open the machine lid - Release the lid lock, located on the
right side of the machine, and allow the lid to lift and remain
open.
3.
Turn the power switch on - Turn
the red switch on the left side of
the machine toward the front,
switching from the
"
0
"
to the
"
1
"
position. The LED Screen on
the control panel will illuminate
showing a symbol.
IMPORTANT:
Do not turn the machine on until the lid lock has
been released. The lid lock feature is used ONLY to keep the lid
closed while the machine is in storage.
Set Up - Adjusting the VP321 Timing Controls
NOTE:
All timing adjustments must be made with the lid lock off and the
lid open.
To adjust/set the timing controls, press the SET button on the control
panel until the required label (Vacuum, Sealing or Cooling) is illuminated.
For each selection, the current time setting will show on the LED Screen. All
time settings are displayed in seconds.
For initial testing, the time settings should be:
Vacuum Time -
40 seconds
Sealing Time -
2.2 seconds
Cooling Time -
3.2 seconds
To change the settings, please read the instructions for each control on
Page 7.
Содержание VP321
Страница 1: ......