background image

10

1.  Verify that the power cord is disconnected from the outlet.  (fi g. 1)

2.  Disconnect the hose from the vacuum.  (fi g. 2) 

3.  Undo the latches and remove the power head from the collection tank.  (fi g. 3)

4.  Clear all dirt or debris from the collection tank and hose.  (fi g. 4)

5.  Check the hose, attachments, and power cord to verify that they have not been damaged.

IMPORTANT! 

 Clean or change the cartridge fi lter regularly for best performance. 

ALWAYS USE 

DUST FILTER FOR DRY VACUUMING.

  If the machine is used without the dust fi lter, the motor 

will burn out and the warranty will be voided.  Always keep spare dust fi lters on hand.

NOTICE!

 The fi lters included are made of high quality materials designed to stop small dust 

particles. The dust fi lter should be used for dry pick-up only. A dry dust fi lter is necessary to pick up 

dust.  If the dust fi lter is wet, it will clog quickly and be diffi cult to clean.  Handle the fi lter carefully 

when removing it for cleaning or replacing. Check the fi lters for tears or small holes. A small hole 

can let dust pass through and out of the cleaner. Do not use a fi lter with holes or tears in it; replace 

it immediately. 

CARE AND MAINTENANCE

WARNING:

  ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE 

REMOVING THE POWER HEAD FROM COLLECTION TANK.

Содержание VJC809PF

Страница 1: ... Cleva North America Inc 601 Regent Park Court Greenville SC 29607 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference Model No VJC809PF Operator s Manual Wet Dry Vacuums ...

Страница 2: ...ormance This vacuum is capable of picking up liquids and dry materials FOR YOUR SAFETY CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS We take pride in producing a high quality durable product This Vacmaster product carries a limited two 2 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or...

Страница 3: ... to a service center Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run Wet Dry Vac over cord Do not handle plug or the Wet Dry Vac with wet hands To reduce the risk of health hazards from vapors or dusts do not vacuum toxic materials Do not use or store near hazardous materials Do not use this Wet Dry Vac with a torn filter o...

Страница 4: ... MOVING PARTS UNPLUG BEFORE SERVICING DOUBLE INSULATED GROUNDING NOT REQUIRED WHEN SERVICING USE ONLY IDENTICAL REPLACEMENT PARTS TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE TO RAIN STORE INDOORS WARNING 4 Length of Extension Cord A W G Wire Size Not recommended 25 Feet 7 5 Meters 50 Feet 15 25 Meters 100 Feet 30 5 Meters 150 Feet 45 7 Meters 110V 120V Amps 0 6 7 10 11 12 13 16 18 18 16 14 ...

Страница 5: ... carton contents list Carton Contents List Key Description Qty A Vac Assembly B 6 Screws Bag C Caster Foot Assembly D Crevice Nozzle E 2 In 1 Utility Nozzle F Foam Sleeve Filter G Handle H Cartridge Filter I Hose J Extension Wand K Operator s Manual NOTE The hose and accessories for this vacuum are 1 25 3 18 cm diameter 1 1 4 1 1 1 1 1 1 2 1 ...

Страница 6: ...ed refer to page 11 for filter installation fig 6 7 7 For wet vacuum cleaning install the supplied foam filter fig 8 See page 11 for filter installation 8 Place the power head back on the collection tank aligning the top section with the clasps and snapping into place by applying downward pressure fig 9 9 Insert the locking end of the hose into the port of the collection tank and turn to lock into...

Страница 7: ...ly mounted With power head removed and in upside down position make sure the filter is pushed in until it stops against the power head and the retainer is installed fig 2 3 Your Wet Dry Vac comes with the cartridge filter pre installed Reference page 11 for installation instructions 3 Place the power head section back on the collection tank and secure it in place using the latches fig 4 OPERATING ...

Страница 8: ...NG INSTRUCTIONS WET VACUUMING 3 Fit the desired nozzle to the vacuum hose fig 3 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 4 5 Turn the motor on by pressing the switch to the I ON position fig 5 6 After use empty the container by unscrewing the drain cap and drain liquids into suitable receptacle or drain fig 6 Remember to refit the drain c...

Страница 9: ... side of the power head and lock into position fig 1 5 Fit the desired extension wand and or nozzle to the vacuum hose fig 2 6 Ensure the power switch is turned off and plug in the power supply fig 3 7 Before turning on the vac firmly hold loose end of the hose Turn the motor on by pressing the switch to the I ON position fig 4 WARNING ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87 1 OR IN CAN...

Страница 10: ...urn out and the warranty will be voided Always keep spare dust filters on hand NOTICE The filters included are made of high quality materials designed to stop small dust particles The dust filter should be used for dry pick up only A dry dust filter is necessary to pick up dust If the dust filter is wet it will clog quickly and be difficult to clean Handle the filter carefully when removing it for...

Страница 11: ...apping or brushing dirt off Cleaning should not be done indoors in living areas For optimal performance a new filter is recommended 4 Install cleaned or new filter into place as instructed above in steps 2 and 3 of Installing Cartridge Filter 5 Wet filters should be removed and allowed to air dry for 24 hours before installing onto the filter cage Installing Foam Sleeve Filter 1 Verify that the po...

Страница 12: ...from motor cover 1 The dust filter is missing or damaged 1 Attach or replace dust filter 2 Vacuum has been used to collect fine dust such as drywall dust fireplace soot or ash without a fine dust filter equipped 2 Remove the standard cartridge filter and install the appropriate fine dust cartridge filter Reduced efficiency and motor speed vibration 1 There is a blockage in the nozzle or hose or th...

Страница 13: ...13 EXPLODED VIEW ...

Страница 14: ... 4 Filter Cage VI02SR 10 06 02 1 5 Cartridge Filter VCFS 1 6 Filter Retainer FV9546 01 20 01 1 7 Collection Tank VOD1PF 20 01 X1 1 8 Drain Cap VB01PF X0 03 1 9 Caster Foot Assembly TVQTJC 16 00 X1 4 10 Crevice Nozzle V1CT 1 11 2 in 1 Utility Nozzle V1UB 1 12 Foam Sleeve Filter VFF51 1 13 Extension Wands Set of 2 V1EW 1 14 Hose V1H6 1 15 Operator s Manual 1 ...