Cleaning Foam Sleeve Filter    

 

1.  With the removed power head in the upside down position, carefully remove foam sleeve filter.  (fig. 4) 
2.  Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water.  

(fig. 5) 

3.  Allow filter to air dry before installing and using again. 

 
 
 
 
 
 

WARNING!

 

TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING 

 

Symptom 

Possible Causes 

Corrective Action 

Vacuum will not operate 

1)  No power supply. 

1)  Check power supply 

– cord, 

breakers, fuses. 

 

2)  Faulty power cord. 

2)  Unplug and check the power 
cord.  If damaged, have it repaired 
by a professional. 

 

3)  Container full. 

3)  Empty container. 

Dust comes out from motor cover. 

1)  The cartridge filter is missing or 
damaged. 

1)  Attach or replace cartridge filter. 

Reduced efficiency and 
motor/speed vibration. 

1)  There is a blockage in the 
nozzle, hose, or the container inlet. 
The cartridge filter is clogged by fine 
dust. 

1)  Check nozzle, hose and 
container inlets for blockage. Take 
off the filter and clean it. Or install a 
new cartridge filter. 

 

 

 
 

TROUBLESHOOTING 

Содержание VJC1210PF

Страница 1: ...anual 12 Gallon Model No VJC1210PF FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www vacmaster com Cleva North America 44 Parkway Commons Greer SC 29...

Страница 2: ...day limited warranty will apply Warranty does not apply to defects due to direct or indirect abuse negligence misuse accidents repairs or alterations and lack of maintenance Please keep your receipt...

Страница 3: ...damaged cord plug or other parts If your Wet Dry Vac is not working as it should has missing parts has been dropped or damaged left outdoors or dropped into water return it to an independent service...

Страница 4: ...WARNING SERVICING OF DOUBLE INSULATED WET DRY VACUUMM WITH A DOUBLE INSULATED WET DRY VACUUM TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING NO GROUNDING MEANS IS PROVIDED ON A DOUBLE INSU...

Страница 5: ...Brush Squeegee I Cartridge Filter J Filter Retainer K Foam Sleeve Filter L 4 Screws Bag M Operator s Manual NOTE The hose and accessories for this vacuum are 2 5 diameter Length of Extension Cord 110V...

Страница 6: ...ters are mounted correctly Do not over tighten screw fig 5 6 Your vacuum comes ready for dry vacuum cleaning If cartridge filter is not installed refer to page 10 for filter installation fig 6 7 7 For...

Страница 7: ...T DO NOT VACUUM TOXIC MATERIALS 1 Verify that the power cord is disconnected from the outlet fig 1 2 In order to prepare your vacuum for dry vacuuming verify that the cartridge filter is securely moun...

Страница 8: ...G 3 Fit the desired nozzle to the vacuum hose fig 3 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 4 5 Turn the motor on by flipping the switch to...

Страница 9: ...blowing port on the back side of the power head and lock into position fig 3 6 Fit the desired extension wand and or nozzle to the vacuum hose fig 4 7 Ensure the power switch is turned off and plug in...

Страница 10: ...er the filter cage with the flat end of the filter towards the vacuum power head Carefully push filter in until it stops against the power head g 2 3 4 Place filter retainer on top of cartridge filter...

Страница 11: ...l not operate 1 No power supply 1 Check power supply cord breakers fuses 2 Faulty power cord 2 Unplug and check the power cord If damaged have it repaired by a professional 3 Container full 3 Empty co...

Страница 12: ...12 EXPLODED VIEW AND PARTS...

Отзывы: