5.2.6 View the maximum and minimum values
After entering the user parameter setting, switch to MAX parameter and press the Set key to display the maximum
temperature in the current time period; After entering user parameter setting, switch to MIN parameter and press
the Set key to display the minimum temperature in the current time period;
After entering user parameter setting, switch to CLR parameter and press the Set key to adjust the parameter to 0.
Then long press the Set key, and the maximum and minimum values of temperature are cleared and the data will
be recorded again.
5.2.7 Temperature setting
Press UP/DOWN button until SET appears after unlocked, then press OK to setting.
The value in SET is the current set temperature.
5.2.8 High/Low temperature alarm.
a
、
If the displayed temperature > SET tempe high temperature alarm SET value H, then the buzzer will
alarm and the digital tube will flash the high temperature alarm code "H1" alternately at the interval of 3
seconds each time.
The high temperature alarm SET value H can be set.
b
、
If the displayed temperature <SET temperature - Low temperature alarm SET value L, then the buzzer will alarm
and the digital tube will flash the low temperature alarm code "L1" alternately at the interval of 3 seconds each
time.
The low temperature alarm SET value L can be set.
5.2.9 Setting of electric heating door
Door heating mode “P1” is set to “1”: Every time the door is opened and closed, it will be heated for T9 minutes. If
the door is opened and closed again during the heating period, the heating time will be reset
Door heating mode “P1” is set to “2” :When the compressor is running, door heater will start working. When the
compressor is shut down, the heater will be shut down after 1 minute delay.
Door heating mode “P1” is set to “3”(disabled in this model) : When the humidity in the cabinet is higher than 80%,
the door heating will be opened, when the humidity in the cabinet is lower than 60%, the door heating will be
closed; When the humidity sensor is faulty or shielded, the door heating stays on.
Door heating mode “P1” is set to “4” : The door heating stays on.
Door heating mode “P1” is set to “4” : The door heating stays off.
The default setting of “P1” is set to “2”, if there is a serious condensation problem, please set “P1” to “4”.
5.2.10 Temperature record.
The recorder stores data every SCy minute(s). When the SCy is 0, the recorder will be shielded. After the shielding
recorder is cancelled Time of recorder needs to be redesigned: year/month/day/hour/minute.
5.2.11 Start the recorder
When the key is unlocked, when the recorder is not started, the digital tube gives flashing alarm and displays “LoF”.
Then press the Set / Mute key and Up key for 3s at the same time, and the digital tube stops displaying “LoF”.
5.2.12 Every time when the pharmacy refrigerator reconnected to power after a power failure, display automatically
shows 1
、
2
、
3
、
4
、
5
、
6
、
7
、
8
、
9
、
n in turn, users can set parameters as in below table while n is displayed.
”Year” setting example(set year to 2022)