7
CHARGE AMPS SELECTION
The vehicle will charge at that recharging speed or at a lower speed depending on the maximum
recharging capacity of the vehicle and the percentage of load it is in. The maximum speed
selected must be in accordance with the installation performed.
It can be modified easily by opening the back cover. The vehicle will charge at this charging speed
or at a lower one, depending on the maximum charging capacity available in the vehicle and the
percentage of charge it is in. The maximum speed selected must be in accordance with the
installation carried out.
The protections to be installed and the cable section must be chosen by a specialist, this table
serving only as a reference. See section 6.
The charging post has protections for each socket of 32 Amps Magneto-thermic Switch and 40
Amps 0.03 mA Super-immunized Differential. Each socket has its own separate protections.
7.1
INSTALLATION OF THE CHARGING POINT
1.
Open the side cover by removing the two fastening screws. Remove and insert the cover
in a tilting way.
2.
Fixing materials are not included in the charging point. Those considered the most
suitable for the material to be fixed should be used. In the case of concrete, the use of
dowels and screws is recommended. An interesting recommendation is to use a
chemical anchor.
3.
Fix the charging point to the ground.
Single-phase power (kW)
1,4 2,8 3,2 3,7 4,1
4,6
5
5,5
6
6,4
7,7
Three-phase power (kW)
4,2 8,4 9,7 11
12,2 13.8 15
16,5 18
19,2 22
Protections to be installed
10
16
16
16
20
20
25
25
32
32
32
Minimum cable cross-section
(mm2)
2,5 2,5 2,5 2,5 4
4
6
6
6
6
10
An electrical specialist technician
must select the circuit breaker
you need to install and the supply
section.