E
N
G
L
IS
H
11
LED SIGNALS ON THE BASE UNIT
Status
GREEN LED
RED LED
YELLOW LED
Possible actions
Operative
(normal
operation)
- Slow flashing if the
network is not
configured.
- One flash for each
transmission received
from a sensor.
Fixed and on, under
alarm conditions.
Rapid flashing in the
case of low battery.
Off.
Briefly press the PROG key to switch to
network configuration mode.
Press and hold the PROG key for some
time to delete the network.
Pressing and holding the STOP key,
briefly press the PROG key to enter TEST
mode (if the network is configured) or
to configure the radio channel (if the
network is not configured)
Network
configuration
Slow flashing until
the first sensor is
inserted, then one
flash for each
message received.
Flashing.
Off.
Pressing the PROG key returns to
working mode.
After 15 seconds inactivity, the device
returns to working mode.
Deleting the
network
Slow flashing.
Slow flashing.
Off.
Pressing the PROG key returns to
working mode.
After 5 seconds inactivity, the device
returns to working mode.
TEST mode
(network
configured)
On and fixed.
Fixed and on, under
alarm conditions.
Rapid flashing in the
case of low battery.
Sequence of from 1 to
16 flashes to indicate
the channel on which
the network is
configured.
Pressing the PROG key accesses
scanning time configuration.
Channel
programming
(network not
configured)
One, two or three
flashes to indicate
channel quality
(quality above mean
level)
One, two or three
flashes to indicate
channel quality
(quality below mean
level)
Sequence of from 1 to
16 flashes, repeated
every second, to
indicate which channel
is having the quality
displayed
Pressing the UP or DOWN keys selects
the desired radio channel.
Pressing the PROG key memorises the
current channel and accesses scanning
time configuration.
Communication
time
configuration
Scanning time code
set:
1 flash = 0.25 s
2 flashes = 0.5 s
3 flashes = 1 s
4 flashes = 15 s
Off
Fixed
Pressing the UP key increases the
scanning time. Pressing the DOWN key
reduces it.
Pressing the PROG key confirms the
time set and returns to working mode.
LOW BATTERY SIGNAL
If the battery for one of the sensors is low, the control unit can emit 2 types of signals:
1.
If dip-switch 7 is set to OFF, when a cycle is activated, the flashing unit starts flashing
2.
If dip-switch 7 is set to ON, when a cycle is activated, the courtesy light flashes 4 times