8.10 - ELECTRIC CONNECTIONS
A1
Antenna shield
A2
Antenna
J1
Safety ribbons.
N.C. contact or conductive rubber ribbons
J2
Opening control for the connection of control
devices with N.O. contact
J3
Stop command. N.C. contact
J4
Common (-)
J5
Photocell. N.C. contact
J6 - J7
Power output 24 VAC for photocells and other
accessories
J7 - J8
Photocell TX power supply for functional test
J7 - J9
Warning light
B1 - B2
Dry contact for light output
L
Power phase
N
Neutral
F1
T1,6A
MAINS
It shows that the control unit is power supplied
OVERLOAD
It shows that there is an overload on accessories
power supply