ENGLISH
- 7 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
r L
RELAY OUTPUT SELECTION
It enables the user to select one of the four relay outputs available: the
transmitters that are about to be saved subsequently will be associated to the
relay selected
1
1
Relay output 1
2
Relay output 2
3
Relay output 3
4
Relay output 4
Fun
FUNCTIONS :
It enables the user to select one of the following functions
Mon
Mon
MONOSTABILE : it activates the corresponding relay through the time of
access device transmission. When the transmission stops, the relay goes
automatically off.
biS
BISTABILE : it activates the corresponding relay on the first access device
transmission. The relay goes off on the second transmission
t iM
1” - 7’30”
TIMER : Access device transmission activates the corresponding relay that is
disabled automatically after a time that can be set from 1.0” to 7’30 with the
following intermediary steps: 1.0” - 2.0” - 3.0” - 4.0” - 5.0” - 6.0” - 7.0”
- 8.0” - 9.0” - 10.0” - 11.0” - 12.0” - 13.0” - 14.0” - 15.0” - 30.0” - 1’00 -
1’30 - 2’00 - 2’30 - 3’00 - 3’30 - 4’00 - 4’30 - 5’00 - 5’30 - 6’00 - 6’30 - 7’00
- 7’30
tEL
0 - 1007
ACCESS DEVICES (save and delete)
To memorize
the access devices proceed as follows:
1.
When on display is shown
t EL
press the MENU key:
on display is shown the memory cell
0000
NOTE:
the occupied memory cells are displayed discontinuously
2.
Should you intend to save the new access device into a specific memory
cell, select the desired cell and proceed. If no specific cell was selected, the
access device is memorized in the first cell available.
3.
Send data with the access device that you intend to save in the memory:
the memory cell in which the new access device was saved is flashing on
display
4.
Send data with the other access devices to be memorized:
the occupied memory cell is flashing on display
To delete
the access device saved in the memory, proceed as follows:
1.
Select the memory cell to be deleted: the cell is flashing on display
2.
Hold the MENU key pressed until the cell is displayed steadily
CLt
DELETE ALL
This menu enables deleting all access device saved in the memory
no
no
Deletion is not completed
Si
Deletion in progress: on display is shown
CLr
until the operation is
completed
rLC
ROLLING CODE mode
WARNING:
if VRD / PROKSIMA is used as a control device, the rolling code
mode has always to be not activated
no
no
ROLLING CODE mode disabled
Si
ROLLING CODE mode enabled
End
Exit the programming menu
no
no
Do not exit the programming menu
Si
Exits the programming menu by storing the parameters set