ENGLISH
4
DESCRIPTION OF THE CONTROL UNIT
The EASY1 control unit is an innovative V2 product guaranteeing
safety and reliability for roller shutters
• 230V - 50Hz or 120V - 60Hz power supplies, depending on
the model, for 1 single phase motor (700W).
• 2 inputs for key selector switch or button activation.
• Programmable operational logic JUMPER (J1).
• Provided with a 433.92 MHz super-heterodyne radio receiver.
• Functioning by means of Personal Pass transmitters.
TECHNICAL SPECIFICATIONS
230V models 120V models
Power supply
230V / 50Hz
120V / 60Hz
Max motor load
700W
700W
Working temperature
-20 ÷ +60 °C
-20 ÷ +60 °C
Dimensions / Weight
127 x 41 x 24 mm / 100 g
Protection
IP55
IMPORTANT REMARKS
For any installation problem please contact our Customer Service
at the number
+39-0172.812411
operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or
wrong installation.
Please read this instruction manual very carefully
before installing and programming your control unit.
• This instruction manual is only for qualified technicians,
who specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service
should be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1
(Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices,
test methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply.
The standards require a separation of the contacts
of at least 3 mm in each pole (EN 60335-1).
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of
accidental detachment of a conducting wire, dangerous
voltage parts will not come into contact with safety low
voltage ones.
• The plastic case has an IP55 insulation; to connect flexible
or rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (EEC Machine Directive 89/392, Annex IIA).
• The automated vehicular gates shall comply with the
following rules: EN 12453, EN 12445, EN 12978 as well
as any local rule in force.
• Also the automation upstream electric system shall comply
with the laws and rules in force and be carried out
workmanlike.
• Always remember to connect the earth according to
current standards (EN 60335-1, EN 60204-1).
DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that EASY1 products conform to the
essential requirements established in the following directives:
- 89/336/CEE (EMC Directive in accordance with standards
EN 61000-6-2, EN 61000-6-3 + EN 50336)
- 2006/95/CEE (Low Voltage Directive in accordance with
standards EN 60335-1 + EN 60335-2-97)
- 99/05/CEE (Radio Directive in accordance with standard
EN 301 489-3)
Racconigi, 12/11/2009
V2 S.p.A. legal representative.
Cosimo De Falco
OPERATIONAL LOGICS
The operational logics are set using jumper
J1
(inserted or
removed) and the connected buttons.
The control unit is set to work with 2 buttons (Fig.1).
To configure the control unit to operate with just 1 button,
proceed as follows:
PLEASE NOTE: The following procedure deletes all
stored transmitters
1.
Connect the button as shown in figure 2
2.
Run the “DELETION OF CODES FOR 1 BUTTON OPERATION”
procedure
To configure the control unit to operate with 2 buttons, proceed
as follows:
PLEASE NOTE: The following procedure deletes all
stored transmitters
1.
Connect the buttons as shown in figure 1
2.
Run the “DELETION OF CODES FOR 2 BUTTON OPERATION”
procedure
On completion of this first stage, select the desired operational
logic using jumper J1:
Man present with 2 buttons (J1 inserted)
Open Button
7 - 8
Close Button
9 -10
Man present with 1 button (J1 inserted)
Jump terminals 7 - 10
Connect the N.O. button between terminals 7 - 8
Step with 2 buttons (J1 removed)
Open Button
7 - 8
Close Button
9 -10
• By pressing the open button, the logic is:
OPEN-STOP-OPEN-STOP
• By pressing the close button, the logic is:
CLOSE-STOP-CLOSE-STOP
Step with 1 button (J1 removed)
Jump terminals 7 - 10
Connect the N.O. button between terminals 7 - 8
By pressing the button, the logic is:
OPEN-STOP-CLOSE-STOP