DISPLAY
oFF
on
dEF1 dEF2 dEF3
in 1
PHOTOCELL ACTIVE ONLY DURING CLOSING
The intervention of the photocell during the
opening stage is ignored.
The intervention of the photocell during the
closing stage causes the shutter to reopen.
PHOTOCELL ACTIVE DURING OPENING AND
CLOSING
The intervention of the photocell during the
opening phase causes the motor to stop.
When the photocell beam is released, the
automation starts during opening for the work
time set in parameter
t i1
.
The intervention of the photocell during the
closing stage causes the shutter to reopen.
on
oFF
oFF
in 2
PHOTOCELL TEST INACTIVE
The photocell operation test is not
performed
PHOTOCELL TEST ACTIVE
Each time the control unit receives an open or
close command, the PHOTOCELL TEST verifies
that the PHOTOCELL is operating correctly.
If the test fails, the display shows
- L5 -
oFF
oFF
oFF
in 3
MECHANICAL SAFETY EDGE
The L6 input is configured to manage a
mechanical safety edge
RESISTIVE RUBBER / OPTICAL SAFETY EDGE
The L6 input is configured to manage a safety
edge (resistive rubber / optical) with active
operation test.
If the test fails, the display shows
- L6 -
oFF
on
oFF
in 4
FIRE FUNCTION
The L7 input is configured to manage a fire
alarm
ALARM FUNCTION
The L7 input is configured to manage an
anti-theft command
oFF
oFF
oFF
in 5
EDGE / FIRE FUNCTION
The L6 input is configured to manage a safety
edge
The L7 input is configured to manage an alarm
LIMIT SWITCH FUNCTION
The L6 input is configured to manage an
opening limit switch
The L6 input is configured to manage a closing
limit switch
NOTE:
If
in 5
is set
on
the settings of the
in 3
and
in 4
functions, they are not considered
oFF
oFF
oFF
ou 1
FLASHING LIGHT
Output (E1 - E2) is on intermittently (2 Hz) during
opening and closing and during pause mode, if
automatic reclosing is active
COURTESY LIGHT
The output (E1 - E2) is on and fixed during
opening, pause and closure. Having completed
the operating cycle, the light remains on for the
COURTESY LIGHT OFF DELAY time
oFF
on
on
ou 2
END OF CYCLE NON-ACTIVE SIGNAL
At the end of the operating cycle, the control
unit sends no signal
END OF CYCLE ACTIVE SIGNAL
At the end of the operating cycle, the control
unit sends a signal to the WES sensors to activate
ENERGY SAVING mode
oFF
on
oFF
Lo 1
START/STOP LOGIC
The START/UP input controls the STEP or
AUTOMATIC operational cycle based on the
programmed operational logic.
The DOWN input is inactive
UP/DOWN LOGIC
The START/UP input always controls opening
and the DOWN input always controls closing,
independently of the operational logic
programmed.
UP + DOWN when pressed simultaneously is the
same as a STOP command
oFF
on
on
Lo 2
START INACTIVE WHILE OPENING
During opening, the START command
is ignored
START ACTIVE WHILE OPENING
During opening, the START command
interrupts opening (no timer is set for automatic
re-closure)
on
on
on
Lo 3
STEP LOGIC
The start command activates an
OPEN-STOP-CLOSE-STOP-OPEN
operational cycle
AUTOMATIC LOGIC
The start command activates an
OPEN-PAUSE-CLOSE-STOP operational cycle
Closure starts automatically after the pause
time set
oFF
oFF
oFF