background image

E

N

G

L

IS

H

12

OPERATION WITH A TIMER

The control unit allows the connection of a timer for
programming door opening and closing times.

To use this function, it is necessary to set the 

Lo 3

function

(see FUNCTION TABLE) on the AUTOMATIC LOGIC (

on

) and

the 

Lo 5

function on the TIMER (

oFF

)

The timer should be connected between the START (L1) and
COMMON (L3) terminals.

Each time the timer closes the contact, the automation device
opens the door and remains paused until the contract is released.
At this point the countdown starts, for the length of the pause
time set, after which the automation device closes the door.

CASE WITH KEYPAD

The EASY-TOP control units may be installed in cases with
external keypads (accessory codes  171226).
To use the keypad buttons, it is essential to install adapter
171226 as shown in the figure. 
Alternatively, the WES-EASY accessory may be installed (code
35B025), which besides using the keypad allows controlling the
edges by radio using the special sensors (see the WES-EASY
instructions).

The keypad buttons operate in parallel with the terminal controls.
These all remain active,
including the STOP command, and must be jumpered to ground
if not used.

Versions supplied with keypads also allow the automation device
to operate in DEAD MAN mode should the safety devices
malfunction.
By pressing and holding the button on the keypad, the
automation device is activated after 5 seconds, overriding the
safety devices; the motor stops immediately as soon as the
button is released. 

NOTE: This function is also available from the terminal
board if the 

Lo 5

function is set to EMERGENCY

CABLE GLAND ASSEMBLY

The casing can accept 4 cable glands in the special easy-break
housings. The type of cable gland is indicated in the figure.

m

PLEASE NOTE:

• Remove the electronic circuit board before drill the casing.
• Drill the container using a suitably sized cutter, according to 

the dimensions of the cable gland.

• Fix the cable glands using the special nuts.

Содержание EASY-TOP

Страница 1: ...v2home com www v2home com CENTRALE DI COMANDO DITALE PER SERRANDE AVVOLGIBILI DIGITAL CONTROL UNIT FOR ROLLER SHUTTERS ARMOIRE DE COMMANDE DIGITALE POUR STORES CUADRO DE MANIOBRAS DIGITAL PARA PERSIAN...

Страница 2: ...rules EN 12453 EN 12445 EN 12978 as well as any local rule in force Also the automation upstream electric system shall comply with the laws and rules in force and be carried out workmanlike The door t...

Страница 3: ...ENGLISH 10 ELECTRIC CONNECTIONS mWARNING Normally closed inputs STOP L2 PHOTOCELL L5 EDGE L6 FIRE L7 if not used must be bridged through the COMMON terminal L3 L8...

Страница 4: ...ordance with the following table After having made the connections power up the main control unit and adjust the power using the trimmer TR1 located on the control unit so as to obtain optimal edge op...

Страница 5: ...5B025 which besides using the keypad allows controlling the edges by radio using the special sensors see the WES EASY instructions The keypad buttons operate in parallel with the terminal controls The...

Страница 6: ...SEL keys To access the programming menu press the MENU key until the display shows in 1 To change the value of this parameter press the MENU key the display shows the currently set value on oFF Selec...

Страница 7: ...L6 input is configured to manage an opening limit switch The L6 input is configured to manage a closing limit switch NOTE If in 5 is set on the settings of the in 3 and in 4 functions they are not con...

Страница 8: ...tive safety keep the command active for 5 seconds the control unit then activates dead man mode and the shutter moves as long as the switch is held When the command is suspended the control unit retur...