background image

ENGLISH

- 10 -

EU DECLARATION OF CONFORMITY 
AND DECLARATION OF 
INCORPORATION OF PARTLY 
COMPLETED MACHINE  

Declaration in accordance with Directives: 2014/35/UE (LVD); 
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B

The manufacturer (*) V2 S.p.A., headquarters in Corso Principi di 
Piemonte 65, 12035, Racconigi (CN), Italy

Under its sole responsibility hereby declares that:
the partly completed machinery model(s): 
DRYS390-R,  DRYS390-B
DRYS390-R-120V,  DRYS390-B-120V

Description: hydraulic actuator for gates

•  is intended to be installed on gates, to create a machine 

according to the provisions of the Directive 2006/42/EC. 
The machinery must not be put into service until the final 
machinery into which it has to be incorporated has been 
declared in conformity with the provisions of the Directive 
2006/42/EC and 89/106/CE.

•  is compliant with the applicable essential safety requirements 

of the following Directives:

 

Machinery Directive 2006/42/EC (annex I, chapter 1)

 

Low Voltage Directive 2014/35/EU

 

Electromagnetic Compatibility Directive 2014/30/EU

 

Directive ROHS2 2011/65/CE

The relevant technical documentation is available at the national 
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65, 12035, Racconigi (CN), 
Italia

The person empowered to draw up the declaration and to provide 
the technical documentation:

Antonio Livio Costamagna

Legal representative of V2 S.p.A.
Racconigi, il 01/06/2015

DRYS390-R

DRYS390-B

DRYS390-R-120V DRYS390-B-120V

Max. leaf length

m

7

5

7

5

Max. leaf weight

Kg

700

700

700

700

Hydraulic block

no

opening

closing

no

opening

closing

Pump capacity

l/m

1

1

1,5

1,5

Hydraulic oil

Total 52-AT42

Total 52-AT42

Total 52-AT42

Total 52-AT42

Power supply 

Vac - Hz

230 - 50/60

230 - 50/60

120 - 50/60

120 - 50/60

Max. absorption

A

1,9

1,9

2,5

2,5

Electric power

W

350

350

350

350

Leaf opening time 0 ÷ 90°

s

30

30

30

30

Condenser 

µF

10

10

31,5

31,5

Max. drive stroke

mm

390

390

390

390

Drive speed

m/s

0,013

0,013

0,016

0,016

Max. thrust 

N

7800

7800

7000

7000

Operating temperature

°C

-25 ÷ +70

-25 ÷ +70

-25 ÷ +70

-25 ÷ +70

Level of protection

IP

55

55

55

55

Working Cycle

%

80

80

80

80

Engine weight

Kg

10

10

10

10

TECHNICAL DATA

Содержание DRYS390-R

Страница 1: ...ame In the event of interventions on automatic or differential breakers or fuses it is essential that faults be identified and resolved prior to resetting In the case of faults that cannot be resolved...

Страница 2: ...omated closure which is thus located on public land For example the access gate to a supermarket or an office or a hospital PROTECTION A Closure is activated by means of a control button with the pers...

Страница 3: ...14 35 EU Electromagnetic Compatibility Directive 2014 30 EU Directive ROHS2 2011 65 CE The relevant technical documentation is available at the national authorities request after justifiable request t...

Страница 4: ...res from 10 to 20 metres from 20 to 30 metres 230V 120V power supply 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 230V 120V motor power supply 4G x 1 5 mm2 4G x 1 5 mm2 4G x 2 5 mm2 Photocells TX 2 x 0 5 mm...

Страница 5: ...t fig 2 4 Release the actuator 5 Pull out the chrome stem as far as it will go 6 Reblock the actuator 7 Mount the front attachment on the stem Fig 3 8 Close the gate leaf and keeping the actuator perf...

Страница 6: ...0 150 390 115 170 160 110 390 125 130 170 80 390 If the dimensions of the pillar or the position of the hinge dimension D do not allow to contain the dimension A to the desired size a niche must be ma...

Страница 7: ...ry to manually operate the gate for the absence of electrical current or an automation failure you must act on the release device as follows 1 open the release cover cap and insert the supplied key 2...

Отзывы: