Courtesy lights

Thanks to the output COURTESY LIGHT
the control unit 

City4

allows the

connection of an electric appliance (e.g.
courtesy light or garden lights), controlled
automatically or by means of the special
transmitter key.

t.LUC

the relay closes when a start or a 
pedestrian start control is given 
and opens after the set time. It 
works in the same way whit a 
remote control on channel 4.

CiCL

the relay keeps closed during the 
whole opening/closing phase. In 
case of intervention of a remote 
control on channel 4, it keeps 
closed for the time set by item 
T.LUC

AUS 

auxiliary output with settable 
operation logic 

In this last case, the COURTESY LIGHT
output becomes an auxiliary output to
which it is possible to link one of the
following operation logics:

tiM

TIMER the relay closes when a remote control arrives on channel 4 and opens after the set time

biSt

BISTABLE the relay changes each time a remote control arrives on channel 4

Mon

MONOSTABLE the relay keeps closed until a signal given by the remote control on channel 4 arrives.

Blinker during pause time

Blinker usually operates during the gate motion only; however, if this
function is enabled, blinker will be on during the pause time too.

Start input function

This menu allows selecting input operation modes (see paragraph
“Activation inputs”):

StAn

Start and Pedestrian Start input standard operation,
according to menu setups.

no

Start inputs from terminal board are disabled. Radio inputs 
operate in 

StAn

mode.

AP.CH

Start impulse always controls the opening phase, Pedestrian 
Start always controls  the closing phase.

PrES

Manned operation; the gate will open as long as the Start 
input stays closed and it will close as long as Pedestrian 
Start stays closed.

oroL

Timer-operation; the gate stays open while the Start input or 
Pedestrian Start input is closed; as soon as the contact 
opens, the pause count down will start.

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание city4

Страница 1: ...LLE POUR LE CONTROLE D UN MOTEUR A 230V 120V UNIVERSELLE ZENTRALE EINHEIT ZUM STEUERN EINES 230V 120V MOTORS CUADRO DE MANIOBRAS DIGITAL UNIVERSAL PARA UN MOTOR 230V 120V I GB F D E City4 Pr 2 0 IL n...

Страница 2: ...ISTRUZIONI 1 INSTRUCTIONS 23 NOTICES 45 ANLEITUNGEN 67 INSTRUCCIONES 89 I GB F D E...

Страница 3: ...RTESY LIGHTS 23 ELECTRIC LOCK 23 PHOTOCELL 23 SAFETY RIBBONS 24 END OF STROKE 24 STOP 24 ACTIVATION INPUTS 24 PLUG IN RECEIVER 25 EXTERNAL AERIAL 25 ADI INTERFACE 25 CONTROL PANEL 25 USE OF DOWN MENU...

Страница 4: ...We recommend to make use of an emergency button to be installed by the automation connected to the control unit STOP input so that the gate may be immediately stopped in case of danger Always remembe...

Страница 5: ...120V 40W for model City4 120V blinker equipped with intermittence inside Connect blinker cables to terminals G6 and G7 of the control unit COURTESY LIGHTS Thanks to the output COURTESY LIGHT the cont...

Страница 6: ...e again you will need a start command if the start function in pause is disabled it will be temporarily enabled to allow the gate release Connect the stop switch cables between terminal P3 and P4 of t...

Страница 7: ...ANS433 or ANSGP433 in order to guarantee the maximal range Connect the antenna hot pole to terminal A2 of the control unit and the braiding to terminal A1 INTERFACE The ADI Additional Devices Interfac...

Страница 8: ...by holding down the UP key items will scroll fast backwards until item dEF is viewed In this way you can quickly reach either the top or bottom of the list There are the following three kinds of menu...

Страница 9: ...abled or if you realize that they do not signal the position to the control unit you must send a START command must be sent when the gate reaches its fully closed position mWARNING if the function PHO...

Страница 10: ...ceives a Start Pedestrian command it will use this time to close the gate Max allowed time to be setup is t CH1 To avoid that the door does not close completely we recommend to setup a longer time tha...

Страница 11: ...otion Motor power This menu allows adjusting the motor power The displayed value is the percentage of max motor power m WARNING In case an hydraulic motor is used set value 100 Start off When the gate...

Страница 12: ...Select option no to set up the always open operation logic Slowing down time In case this function is enabled during the last seconds of motion the control unit will give motor a reduced power command...

Страница 13: ...ways ignored during a total opening Closing after transit During the automatic operation the pause count down starts from the set up value each time a photocell operates during the pause If the photoc...

Страница 14: ...opens after the set time biSt BISTABLE the relay changes each time a remote control arrives on channel 4 Mon MONOSTABLE the relay keeps closed until a signal given by the remote control on channel 4 a...

Страница 15: ...for the closing phase only Warning if you select this option you must disable photocell test Test of safety devices In order to achieve a safer operation for the user the unit performs a safety devic...

Страница 16: ...the disabled function then activate its closing and see after how many seconds the photocell operates Set up a slightly lower time into i ShA menu and a slightly higher time into F ShA menu During th...

Страница 17: ...f stroke Obstacle Sensor Enabling This menu allows the sensitivity adjustment of the obstacle sensor over 10 levels from 1 to 10 By setting up 0 sensors will be disabled increasing the value the sensi...

Страница 18: ...e setup be increased or decreased of 1000 units The previous displayed count will get lost Signal of service required As soon as the counter of cycles before the next request for service is zero the c...

Страница 19: ...1 Remove the extractable part containing terminals P1 to P14 OVERLOAD led will switch off 2 Remove the overload cause 3 Reinsert the terminal board extractable part and check that this led is not on...

Страница 20: ...E 0 0 3 0 Fast closing time after slowing down during closing 1 0 0 0 St AP Start in opening PAUS PAUS no Start command is not available ChiU Command close gate PAUS Stop the gate and goes in pause St...

Страница 21: ...bled the control unit ignores it rESi Input enabled for conductive rubber ribbons StAn Input enabled for standard safety ribbons with normally closed contact AP Ch Input enabled in opening and closing...

Страница 22: ...ng end of stroke N C contact P9 Common P10 P11 Power output 24 VAC for photocells and other accessories P11 P12 Photocell TX power supply for functional test P13 P14 Electric lock 12VAC G1 G2 Courtesy...

Отзывы: