EU DECLARATION OF CONFORMITY 
AND DECLARATION OF 
INCORPORATION OF PARTLY 
COMPLETED MACHINE  

Declaration in accordance with Directives: 2014/35/UE (LVD); 
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B

The manufacturer (*) V2 S.p.A., headquarters in Corso Principi di 
Piemonte 65, 12035, Racconigi (CN), Italy

Under its sole responsibility hereby declares that:
the partly completed machinery model(s): 

CALYPSO400-230V (*), CALYPSO500-230V (*)
CALYPSO600-230V (*)
CALYPSO400-120V (*), CALYPSO500-120V (*)
CALYPSO600-120V (*)
CALYPSO400-24V (*), CALYPSO500-24V (*)
CALYPSO600-24V (*)

Description: electromechanical actuator for gates

•  is intended to be installed on gates, to create a machine 

according to the provisions of the Directive 2006/42/EC. 
The machinery must not be put into service until the final 
machinery into which it has to be incorporated has been 
declared in conformity with the provisions of the Directive 
2006/42/EC and 89/106/CE.

•  is compliant with the applicable essential safety requirements 

of the following Directives:

 

Machinery Directive 2006/42/EC (annex I, chapter 1)

 

Low Voltage Directive 2014/35/EU

 

Electromagnetic Compatibility Directive 2014/30/EU

 

Directive ROHS2 2011/65/CE

The relevant technical documentation is available at the national 
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65, 12035, Racconigi (CN), 
Italia

The person empowered to draw up the declaration and to provide 
the technical documentation:

Antonio Livio Costamagna

Legal representative of V2 S.p.A.
Racconigi, il 01/06/2015

(*) made in extra EU Countries on behalf of V2 S.p.A.

TECHNICAL DATA

CALYPSO
400-230V

CALYPSO
500-230V

CALYPSO
600-230V

CALYPSO
400-120V

CALYPSO
500-120V

CALYPSO
600-120V

CALYPSO

400-24V

CALYPSO

500-24V

CALYPSO

600-24V

Max. leaf lenght

m

2,5

3

4

2,5

3

4

2,5

3

4

Max. leaf weight

Kg

400

500

500

400

500

500

300

400

400

Power supply

Vac - Hz 230 - 50

230 - 50

230 - 50

120 - 60

120 - 60

120 - 60

24 Vdc

24 Vdc

24 Vdc

Idling current

A

0,8

0,8

0,8

2

2

2

2

2

2

Full load current

A

1,2

1,2

1,2

2,8

2,8

2,8

10

10

10

Electric power

W

200

200

200

300

300

300

-

-

-

Opening time of the 
leaf 0÷90°

s

22

25

30

22

25

30

22

27

35

Capacitor 

µF

8

8

8

25

25

25

-

-

8

Max travel

mm

400

500

600

400

500

600

400

500

600

Operating speed

m/s

0,016

0,016

0,016

0,018

0,018

0,018

-

-

-

Maximum thrust

N

2300

2300

2300

2300

2300

2300

2000

2000

2000

Working temperature

°C

-30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50

Protection

IP

44

44

44

44

44

44

44

44

44

Working cycle

%

30

30

30

30

30

30

90

90

90

Motor weight

Kg

6,5

6,8

7,1

6,5

6,8

7,1

6,3

6,6

7,1

Содержание CALYPSO Series

Страница 1: ...ILS BATTANTS E OPERADOR ELECTROMEC NICO IRREVERSIBLE PARA CANCELAS BATIENTES P ACTUADOR ELECTROMEC NICO IRREVERS VEL PARA PORT ES DE BATENTE D NICHT UMKEHRBARER ELEKTROMECHANISCHER ANTRIEB F R FL GELT...

Страница 2: ...177 mm 120 mm A B C 1 2 5 m m 13 mm 120 mm 59 5 mm 6 mm 6 mm 10 mm 8 5 mm 80 mm 50 mm CALYPSO 400 500 600 A 819 944 1044 B 762 887 987 C 1162 1387 1644...

Страница 3: ...ame In the event of interventions on automatic or differential breakers or fuses it is essential that faults be identified and resolved prior to resetting In the case of faults that cannot be resolved...

Страница 4: ...omated closure which is thus located on public land For example the access gate to a supermarket or an office or a hospital PROTECTION A Closure is activated by means of a control button with the pers...

Страница 5: ...e relevant technical documentation is available at the national authorities request after justifiable request to V2 S p A Corso Principi di Piemonte 65 12035 Racconigi CN Italia The person empowered t...

Страница 6: ...ply 230V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 230V motor power supply 4G x 1 5 mm2 4G x 1 5 mm2 4G x 2 5 mm2 24V motor power supply 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 Photocells TX 2 x 0 5 mm2 2...

Страница 7: ...revious page mark them on the pillars and continue as follows Fix the clamps to the pillar and to the gate soldering directly if the material does not allow it it is necessary to solder the clamps to...

Страница 8: ...ASE In case of a blackout the gate can be operated directly from the motor Insert the key supplied in the lock perform 1 2 of a turn To restore the automation simply rotate the key in closed position...

Страница 9: ...61...

Страница 10: ...30 1010 150 140 1000 170 150 990 190 150 980 200 150 980 210 140 980 250 120 1010 g max B mm C mm F mm 100 130 170 970 150 180 960 170 180 960 190 170 970 210 140 990 g max B mm C mm F mm 110 130 190...

Страница 11: ...100 175 190 1390 195 200 1370 215 220 1360 235 235 1350 255 255 1330 275 270 1300 g max B mm C mm F mm 110 195 200 1370 215 220 1360 235 235 1350 255 250 1335 g max B mm C mm F mm 100 130 160 1210 15...

Страница 12: ...64 B F C...

Страница 13: ...00 110 130 130 1027 110 110 130 140 1057 g max B mm C mm F mm 80 130 100 995 85 130 110 1005 90 130 120 1015 95 130 130 1025 100 130 140 1035 110 130 150 1045 g max B mm C mm F mm 100 200 200 1340 220...

Страница 14: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...

Отзывы: