10 - EMERGENCY DEAD MAN OPERATION

This operational mode can be used to move the gate in DEAD 
MAN mode in particular cases, such as installation/maintenance or 
in the case of malfunctioning of photocell, edge, limit switches or 
encoder.

To activate the function the START command must be pressed 
3 times (presses must last at least 1 second; the pause between 
commands must last at least 1 second). 

1”

1”

1”

T

>1”

>1”

>1”

The fourth START command activates the gate in MAN PRESENT 
mode. To move the gate keep the START command pressed for 
the duration of the operation (time T). 
The function will automatically turn off after 10 seconds of 
inactivity of the gate.

NOTE: 

if the 

Strt 

parameter is set as 

StAn

, the Start 

command (from the terminal block or remote control) moves the 
gate in the open and closed directions alternatively (unlike the 
normal DEAD MAN mode).

11 - READING OF CYCLE COUNTER

PD19 control unit counts the completed opening cycles of the 
gate and, if requested, it shows that service is required after a 
fixed number of cycles.
There are two counters available:

•  A totalizing counter for completed opening cycles thatcannot 

be zeroed (option 

tot

 of item 

Cont

 )

•  A downward counter for the number of cycles before the next 

request for service (option 

SErv

 of item 

Cont

 ).

This counter can be programmed according to the desired value.
The scheme hereafter shows how to read the totalizing counter, 
how to read the number of cycles before the next service is 
required as well as how to program the number of cycles before 
the next request for service (as for the example shown, the control 
unit completed no. 12451 cycles and there are no. 1300 cycles 
before the next service request.

Area 1 

is the reading of the total number of completed cycles; 

through 

h

 and 

i

 keys, you can alternate the display of thousands 

or units.

Area 2 

is the reading of the number of cycles before the next 

request for service: its value is rounded down to the hundreds.

Area 3 

is the setup of this latter counter; on first pressing the 

h

 or 

i

 key the current value of the counter is rounded to the 

thousand, each press after this increases the setting by 1000 units 
or decreases by 100. The previous displayed count will get lost.

11.1 - SIGNAL OF SERVICE REQUIRED

As soon as the counter of cycles before the next request for 
service is zero, the control unit shows the request for service 
through an additional 5-second pre-blinking. 

This signal will be repeated at each opening cycle, until the 
installer enters into the counter reading and setup menu, and 
possibly programs the number of cycles after which the next 
service will be requested.

In case no new value is setup (that is to say that the counter value 
is left at zero), the signalling function for the service request will 
be disabled and no signal will be repeated anymore.

m

 

WARNING: service operations shall be carried out by 

qualified staff only.

3

2

-Cnt

tot

SEru

ESC

-01.3

-02.0

-01.0

-03.0

1

0 12.

.45 1

Содержание AYROS series

Страница 1: ...PESO GB 230V 120V ELECTRO MECHANICAL IRREVERSIBLE RACK ACTUATOR FOR SLIDING GATES UP TO 1200 KG F OPERATEUR ELECTROMECANIQUE 230V 120V IRREVERSIBLE A CREMAILLERE POUR PORTAILS COULISSANTS JUSQU A 120...

Страница 2: ...200 mm 343 mm 178 mm 226 mm 334 mm 3 mm 328 mm 200 mm 343 mm 160 mm 74 mm 50 mm 100 mm 128 mm 206 mm 283 mm...

Страница 3: ...ITALIANO 26...

Страница 4: ...4 6 PHOTOCELLS 4 7 SAFETY RIBBONS 4 8 EXTERNAL AERIAL 4 9 ELECTRICAL CONNECTION 4 10 PLUG IN RECEIVER 4 11 ADI INTERFACE 5 CONTROL PANEL 5 1 DISPLAY 5 2 USE OF THE KEYS FOR PROGRAMMING 6 ACCESSING TH...

Страница 5: ...make any modifications to any part of the automation device or the accessories connected to it unless described in this manual Any other modifications will void the warranty on the product The instal...

Страница 6: ...are authorised for use and closure is not in a public area Examples of this type are gates inside business premises where the sole users are employees or a part of them who have been suitably informed...

Страница 7: ...tended to be installed on sliding gates to create a machine according to the provisions of the Directive 2006 42 EC The machinery must not be put into service until the final machinery into which it h...

Страница 8: ...1 7 A 2 A 2 6 A 4 3 A Running capacitor 8 F 10 F 12 F 36 F Start off capacitor 18 F 18 F 25 F 75 F Gate maximum speed 0 16 m s 0 16 m s 0 16 m s 0 18 m s Maximum thrust 400 N 670 N 950 N 950 N Duty ci...

Страница 9: ...ace and parallel to the gate 5 Wait for the complete setting of the concrete 6 Unscrew the bolts fixing the base to the clamps and put the motor on the plate 7 Adjust the 4 grains to make the motor be...

Страница 10: ...TOR Check the following points 1 the motor must be on a levelled surface and perfectly parallel to the gate 2 the distance between pinion and rack must be 1 or 2 mm If needed adjust the 4 grains 3 the...

Страница 11: ...it positions the magnet be positioned next to the magnetic sensor behind the hood as near as possible to the hood The supplied magnets have been colored differently in order to be distinguished from e...

Страница 12: ...nticlockwise closing the hatch of the lock then draw it out 4 Close the lock with the hatch J 3 6 INSTALLATION LAYOUT 1 3 E 5 4 A B F D 2 C LENGTH OF THE CABLE 10 metres from 10 to 20 metres from 20 t...

Страница 13: ...es see Strt item of programming menu mWARNING If you use maintained command devices magnetic loop detectors timers presence detectors etc clock mode must be used parameter Strt oroL Standard mode STAR...

Страница 14: ...on photocells power supply must be connected to terminals M11 and M12 of the control unit to carry out the operation test 4 7 SAFETY RIBBONS The control unit considers two kinds of safety ribbons depe...

Страница 15: ...M10 M11 M12 RECEIVER FUSE MAINS OVERLOAD L LINE N NEUTRAL LAMP 230V MAX 40W COURTESY LIGHT CONTACT START START P STOP COM PHOTO 1 PHOTO 2 EDGE 1 EDGE 2 COM 24V 10W 24V Photo Edge Test GND ANT A1 A2 mC...

Страница 16: ...uitable for a command of PD19 control unit CHANNEL 1 g START CHANNEL 2 g PEDESTRIAN START CHANNEL 3 g STOP CHANNEL 4 g COURTESY LIGHT NOTE Before programming 4 channels and function logics read carefu...

Страница 17: ...the START command pressing the i key activates the PEDESTRIAN START command There are the following three kinds of menu items Function menu Time menu Value menu Function menu setup Function menus all...

Страница 18: ...ot2 CoS1 CoS2 according to the safety devices installed on the gate For the position of the item menus inside the main menu and for the options related to each item menu refer to the chapter 12 3 Star...

Страница 19: ...o store the precise position of the range limit it is recommended to activate the slow speed near to the limit The position at which the slow speed is activated is stored as the starting point for slo...

Страница 20: ...to read the totalizing counter how to read the number of cycles before the next service is required as well as how to program the number of cycles before the next request for service as for the exampl...

Страница 21: ...e gate opens leftwards P APP Partial opening 25 0 1 00 The percentage of the path the gate performs in the case of opening using the Pedestrian Start command t PrE Pre blinking time 1 0 0 5 1 00 Befor...

Страница 22: ...pening phase This menu allows fixing the control unit conduct in case it receives a Start command during the opening phase PAUS PAUS The gate stops and goes to pause ChiU The gate immediately starts c...

Страница 23: ...ime adjustable time from 0 5 to 20 0 PA t r Pause after transit no Si In order to let the gate open for the shortest possible time it is possible to stop the gate once the passage before the photocell...

Страница 24: ...cells active both during the opening and closing phase no no Input disabled ignored by the control unit AP Ch Input enabled Fot2 Photocell 2 input This menu allows enabling the input for type 2 photoc...

Страница 25: ...sed rate below the set threshold indicates the presence of an obstacle If set to 0 the obstacle is only detected when the gate is stopped When the sensor intervenes the gate stops and is operated in t...

Страница 26: ...interrupt their beam you should hear the relay tripping Error 4 When a Start command is given and the gate does not open or does a partial opening and the following writing appears on display Err4 Th...

Страница 27: ...iciency of all warning devices the perfect efficiency of all safety devices measurement of the gate operating forces the lubrication of mechanical parts on the automation device where necessary the st...

Страница 28: ...ay vary depending on the intensity of use Any inspection maintenance or repairs should only be performed by qualified personnel Even if you think you know how do not modify the system and the automati...

Страница 29: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...

Отзывы: