AUTOMATION DEVICE INSTALLERS MANUAL

1 - GENERAL SAFETY INFORMATION

Prior to proceeding with installation, it is essential the instructions be read in full, since they contain important information
regarding safety, installation, use and maintenance.

• Anything not expressly described in these instructions is prohibited; unforeseen uses may be a source of danger to people and property.
• Do not install the product in explosive environments and atmospheres: the presence of inflammable gases or fumes is a serious safety 

hazard.

• Do not make any modifications to any part of the automation device, or the accessories connected to it, unless described in this manual.
• Any other modifications will void the warranty on the product.
• The installation steps should be conducted so as to avoid rainy weather, which can expose electronic circuits to dangerous water 

seepage.

• All operations requiring the casing of the device to opened should be performed with the control unit disconnected from the electricity 

supply and with a warning notice displayed, for example: ”CAUTION, MAINTENANCE IN PROGRESS”.

• Avoid exposing the device close to sources of heat and flame. 
• In the event of interventions on automatic or differential breakers or fuses, it is essential that faults be identified and resolved prior to 

resetting. In the case of faults that cannot be resolved using the information to be found in this manual, consult the V2 customer 
assistance service.

• V2 declines all responsibility for failure to comply with good construction practice standards in addition to structural deformation of the 

gate that might occur during use.

• V2 reserves the right to make modifications to the product without prior warning.

• Installation/maintenance personnel should wear individual protection devices (IPDs), such as overalls, safety helmets, boots and gloves.
• The ambient operating temperature should be that indicated in the technical characteristics table. 
• The automation device should be shut down immediately in the event of any anomalous or hazardous situation; the fault or malfunction 

should be immediately reported to the person responsible.

• All safety and hazard warnings on the machinery and equipment should be complied with.
• Electromechanical actuators for gates are not intended to be used by people (including children) with diminished physical, sensory or 

mental capacity, or lacking in experience or knowledge, unless they are under supervision or have been instructed in use of the actuator 
by a person responsible for safety.

• DO NOT introduce objects of any kind into the compartment below the motor cover. 

The compartment should remain free in order to aid with motor cooling.

1.1 - PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED

The automation device should not be used until installation, as specified in “Testing and start-up”, has been performed.
It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus,
prior to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any
structural modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit
zones, and verify that:
• The gate has no friction points, either during closing or opening.
• The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.
• The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the size of the motor 

reducer itself.

• The support on which the automation device will be fixed is solid and durable. 
• The mains power supply to which the automation device is connected has a dedicated safety earthing system and differential breaker 

with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than or equal to 3 mm).

Warning: The minimum safety level depends on the type of use; please refer to the following outline:

Closure use type

Type of activation commands

Group 1

Informed people

(use in private area)

Group 2

Informed people

(use in public area)

Group 3

Informed people

(unlimited use)

Man-present command

A

B

Not possible

Remote control and closure in view 

(e.g. infrared)

C

or 

E

C

or 

E

C

and 

D

or 

E

Remote control and closure not in view 

(e.g. radio)

C

or 

E

C

and 

D

or 

E

C

and 

D

or 

E

Automatic control 

(e.g. timed closure control)

C

and 

D

or 

E

C

and 

D

or 

E

C

and 

D

or 

E

Содержание ALFARISS

Страница 1: ...EUR ELECTROMECANIQUE 24V IRREVERSIBLE A CREMAILLERE POUR PORTAILS COULISSANTS JUSQU A 300 KG DE POIDS MOTOR ELECTROMECANICO 24V IRREVERSIBLES A CREMALLERA PARA PUERTAS CORREDERAS HASTA 300 KG DE PESO...

Страница 2: ......

Страница 3: ...34 4 2 ACTIVATION INPUTS 34 4 3 STOP 35 4 4 CONNECTING PHOTOCELLS 35 4 5 CONNECTING SAFETY RIBBONS 35 4 6 EXTERNAL AERIAL 36 4 7 LOW VOLTAGE LIGHT OUTPUT 36 4 8 COURTESY LIGHTS 36 4 9 POWER SUPPLY 36...

Страница 4: ...y and hazard warnings on the machinery and equipment should be complied with Electromechanical actuators for gates are not intended to be used by people including children with diminished physical sen...

Страница 5: ...t person The risk analysis should take into consideration all danger zones for the automation device which should be appropriately protected and marked In a clearly visible area apply a sign with info...

Страница 6: ...50 Idling current A 0 9 Full load current A 3 Gate maximum speed m s 0 18 Maximum thrust N 330 Duty cycle 50 Pinion M4 Z16 Working temperature C 20 55 Motor weight Kg 7 5 Protection degree IP 44 Maxim...

Страница 7: ...and parallel to the gate 5 Wait for the complete setting of the concrete 6 Unscrew the bolts fixing the base to the clamps and put the motor on the plate 7 Insert the 4 grains with their nuts in the p...

Страница 8: ...gate making sure that they stand at the same height than the motor pinion The rack MUST BE positioned 1 or 2 mm over the pinion of the motor all the gate length 3 4 INSTALLING THE MAGNETIC LIMIT SWITC...

Страница 9: ...restore the automation proceed as follows 1 Turn the key L anticlockwise until reached the limit switch then draw it out 2 Turn the key K anticlockwise closing the hatch of the lock then draw it out...

Страница 10: ...rse the connectors 4 2 ACTIVATION INPUTS PD13 control unit is equipped with two activation inputs START and START P whose operation depends on the programmed operation modes see Strtitem of programmin...

Страница 11: ...control unit Use outputs having normally closed contact mSAFETY RIBBONS INSTRUCTIONS If several edges with normally closed contacts are used the outputs should be connected in series If several conduc...

Страница 12: ...VER PD13 control unit is suitable for plugging in a MRx receiver having a high sensitivity super heterodyne architecture MRx module receiver is provided with 4 channels and each of them is suitable fo...

Страница 13: ...ing traditional devices with N O contact J2 Pedestrian open command for connecting traditional devices with N O contact J3 STOP command N C contact J4 Common J5 Photocell 1 xterior N C contact J6 Phot...

Страница 14: ...explored by using the 3 keys h i and OK located on the side of the control unit display PLEASE NOTE Outside the configuration menu pressing the h key activates the START command pressing the i key ac...

Страница 15: ...ges which will get lost 7 LOADING THE DEFAULT PARAMETERS dEF If necessary it is possible to restore all parameters to their standard or default values see the final summary table m PLEASE NOTE This pr...

Страница 16: ...ached 5 2 The gate will be activated in opening direction until the stop end or the opening end of stroke is reached 5 3 The gate will be activated in closing direction until the stop end or the closi...

Страница 17: ...cell edge limit switches or encoder To start the emergency dead man operating mode activate the start command START for 3 seconds Note if the Strt parameter is set as StAn the Start command from the t...

Страница 18: ...eys you can alternate the display of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup...

Страница 19: ...unction This function is useful for reducing the energy consumption of the automation device while in stand by mode If the function is enabled the control unit will enter ENERGY SAVING mode under the...

Страница 20: ...y of the obstacle sensor When the current absorbed by the motor exceeds the value set the control unit detects an alarm rA AP Slow down in opening 1 5 0 1 00 This menu allows regulating the percentage...

Страница 21: ...the pause If the photocell operates during the opening time this time will be immediately stored as pause time This function allows having a fast closing as soon as transit through the gate is comple...

Страница 22: ...rol unit ProS The input STOP stops the gate pressing the command START the gate continues the motion invE The command STOP stops the gate at the next START the gate starts moving in the opposite direc...

Страница 23: ...reshold indicates the presence of an obstacle If set to 0 the obstacle is only detected when the gate is stopped When the sensor intervenes the gate stops and is operated in the reverse direction for...

Страница 24: ...ed section 4 4 Error 4 When a Start command is given and the gate does not open or does a partial opening and the display shows Err4 It means that the end of stroke is damaged or that the wiring that...

Страница 25: ...com 14 MAINTENANCE Maintenance should be performed in full compliance with the safety instructions described in this manual and in accordance with current legal and regulatory provisions The recommend...